Your browser doesn't support javascript.
loading
Two-tailed RT-qPCR panel for quality control of circulating microRNA studies.
Androvic, Peter; Romanyuk, Nataliya; Urdzikova-Machova, Lucia; Rohlova, Eva; Kubista, Mikael; Valihrach, Lukas.
Afiliação
  • Androvic P; Institute of Biotechnology of the Czech Academy of Sciences - BIOCEV, Vestec, 252 50, Czech Republic.
  • Romanyuk N; Laboratory of Growth Regulators, Faculty of Science, Palacky University, Olomouc, 78371, Czech Republic.
  • Urdzikova-Machova L; Institute of Experimental Medicine of the Czech Academy of Sciences, Prague, 142 20, Czech Republic.
  • Rohlova E; Institute of Experimental Medicine of the Czech Academy of Sciences, Prague, 142 20, Czech Republic.
  • Kubista M; Institute of Biotechnology of the Czech Academy of Sciences - BIOCEV, Vestec, 252 50, Czech Republic.
  • Valihrach L; Department of Anthropology and Human Genetics, Faculty of Science, Charles University, Prague, 128 43, Czech Republic.
Sci Rep ; 9(1): 4255, 2019 03 12.
Article em En | MEDLINE | ID: mdl-30862831
ABSTRACT
Circulating cell-free microRNAs are promising candidates for minimally invasive clinical biomarkers for the diagnosis, prognosis and monitoring of many human diseases. Despite substantial efforts invested in the field, the research so far has failed to deliver expected results. One of the contributing factors is general lack of agreement between various studies, partly due to the considerable technical challenges accompanying the workflow. Pre-analytical variables including sample collection, RNA isolation, and quantification are sources of bias that may hamper biological interpretation of the results. Here, we present a Two-tailed RT-qPCR panel for quality control, monitoring of technical performance, and optimization of microRNA profiling experiments from biofluid samples. The Two-tailed QC (quality control) panel is based on two sets of synthetic spike-in molecules and three endogenous microRNAs that are quantified with the highly specific Two-tailed RT-qPCR technology. The QC panel is a cost-effective way to assess quality of isolated microRNA, degree of inhibition, and erythrocyte contamination to ensure technical soundness of the obtained results. We provide assay sequences, detailed experimental protocol and guide to data interpretation. The application of the QC panel is demonstrated on the optimization of RNA isolation from biofluids with the miRNeasy Serum/Plasma Advanced Kit (Qiagen).
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Controle de Qualidade / Kit de Reagentes para Diagnóstico / Reação em Cadeia da Polimerase em Tempo Real / MicroRNA Circulante Tipo de estudo: Guideline / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Controle de Qualidade / Kit de Reagentes para Diagnóstico / Reação em Cadeia da Polimerase em Tempo Real / MicroRNA Circulante Tipo de estudo: Guideline / Prognostic_studies Limite: Animals / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article