Qualitative and Quantitative Analysis of Cathinones in Human Urine by SPE-GC-MS.
Wang, P; Liu, X Y; Liu, Y; Luo, Y F; Wang, Z.
Afiliação
  • Wang P; Guangzhou Accurate and Correct Test Company, Guangzhou 510663, China.
  • Liu XY; Guangdong Accurate and Correct Institution of Forensic Sciences, Guangzhou 510663, China.
  • Liu Y; Guangzhou Accurate and Correct Test Company, Guangzhou 510663, China.
  • Luo YF; Guangdong Accurate and Correct Institution of Forensic Sciences, Guangzhou 510663, China.
  • Wang Z; Guangzhou Wondfo Biotech Co. Ltd., Guangzhou 510663, China.
Fa Yi Xue Za Zhi ; 34(6): 606-610, 2018 Jun.
Article em En, Zh | MEDLINE | ID: mdl-30896097
ABSTRACT

OBJECTIVES:

To propose an alternative solid phase extraction-gas chromatography-mass spectrometry (SPE-GC-MS) method for the sensitive determination of cathinones in human urine samples, plus methodological verification.

METHODS:

Human urine samples were concentrated by solid phase extraction (SPE) sorbent and converted into the corresponding heptafluorobutyric acid anhydride derivatives. Methcathinone, 4-methyl methcathinone and 3,4-methylenedioxy-N-methylcathinone were detected by gas chromatography-mass spectrometry (GC-MS). With quantitative analysis by internal standard method, methodological verification was carried out from the aspects of specificity, precision and reco-very rate.

RESULTS:

Methcathinone, 4-methyl methcathinone and 3,4-methylenedioxy-N-methylcathinone showed good linearly in the range of 25-200 ng/mL of urine (r>0.99), with the limits of detection 2.0 ng/mL, limit of quantitation 25.0 ng/mL, both intra- and inter-day coefficients of variation lower than 6.0%, and recovery rates of 98.4%-105.7%.

CONCLUSIONS:

he proposed SPE-GC-MS procedure has good accuracy and specificity, can meet the need of qualitative and quantitative analysis of cathinones in the urine of drug abusers, and therefore provide technical support for the detection of cathinone abuse.