Iridocorneal angle assessment of companion rabbits using gonioscopy, spectral-domain optical coherence tomography (Optovue iVue® ), high-resolution ultrasound, and Pentacam® HR imaging.
Li Puma, Margaret C; Freeman, Kate S; Cleymaet, Allison M; Pederson, Samantha L; Crawford, Amanda C; Dinger, Shelby C; Li Puma, Lance C; Johnston, Matthew S.
Afiliação
  • Li Puma MC; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Freeman KS; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Cleymaet AM; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Pederson SL; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Crawford AC; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Dinger SC; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Li Puma LC; Department of Biomedical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
  • Johnston MS; Department of Clinical Sciences, College of Veterinary Medicine, Colorado State University, Fort Collins, Colorado.
Vet Ophthalmol ; 22(6): 834-841, 2019 Nov.
Article em En | MEDLINE | ID: mdl-30938083
ABSTRACT

OBJECTIVE:

Iridocorneal angle (ICA) narrowing is a known risk factor for primary glaucoma in multiple species, but has not been described in companion rabbits. This study aimed to develop an ICA grading scheme for companion rabbits to enable early glaucoma predisposition diagnosis. ANIMALS STUDIED Twenty healthy rabbits of varying breeds and ages. PROCEDURES Rabbits received complete ophthalmic examinations, including gonioscopy, and imaging of the ICA using spectral-domain optical coherence tomography (SD-OCT), Scheimpflug imaging (Pentacam® HR), and high-resolution ultrasound (HRUS). Angle opening distance (AOD) and angle recess area (ARA) of the ICA were measured and assessed for agreement using a Bland-Altman analysis. A five-stage gonioscopy grading scheme was created, and Spearman-rank test assessed for correlation between gonioscopy grades and ICA measurements. Differences among age and sex were analyzed with a nonparametric ANOVA and Wilcoxon rank-sum test, respectively.

RESULTS:

Analysis revealed AOD medians of 0.28mm for SD-OCT [95% CI 0.24-0.31], 0.20mm for Pentacam® HR [95% CI 0.18-0.21], and 0.25mm for HRUS [95% CI 0.22-0.28]. The median ARA was 0.14mm2 for SD-OCT [95% CI 0.117-0.163], 0.09mm2 for Pentacam® HR [95% CI 0.082-0.100], and 0.06mm2 for HRUS [95% CI 0.046-0.054]. The association between gonioscopy grade and SD-OCT ARA was significant (P < 0.05), and there was a significant difference (P < 0.001) between imaging modalities for both ARA and AOD.

CONCLUSIONS:

Gonioscopy grade correlated well with SD-OCT ARA. Therefore, SD-OCT is recommended as a noncontact method for evaluating companion rabbit ICA. Each imaging device should not be used interchangeably for ICA evaluation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Fechado / Tomografia de Coerência Óptica / Gonioscopia Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Glaucoma de Ângulo Fechado / Tomografia de Coerência Óptica / Gonioscopia Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article