Your browser doesn't support javascript.
loading
Preclinical imaging of epidermal growth factor receptor with ABY-029 in soft-tissue sarcoma for fluorescence-guided surgery and tumor detection.
Samkoe, Kimberley S; Sardar, Hira S; Bates, Brent D; Tselepidakis, Niki N; Gunn, Jason R; Hoffer-Hawlik, Kevin A; Feldwisch, Joachim; Pogue, Brian W; Paulsen, Keith D; Henderson, Eric R.
Afiliação
  • Samkoe KS; Department of Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, New Hampshire.
  • Sardar HS; Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire.
  • Bates BD; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
  • Tselepidakis NN; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
  • Gunn JR; Department of Orthaepedics, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire.
  • Hoffer-Hawlik KA; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
  • Feldwisch J; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
  • Pogue BW; Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire.
  • Paulsen KD; Affibody AB, Solna, Sweden.
  • Henderson ER; Department of Surgery, Geisel School of Medicine, Dartmouth College, Hanover, New Hampshire.
J Surg Oncol ; 119(8): 1077-1086, 2019 Jun.
Article em En | MEDLINE | ID: mdl-30950072
ABSTRACT
BACKGROUND AND

OBJECTIVES:

Fluorescence-guided surgery using epidermal growth factor receptor (EGFR) targeting has been performed successfully in clinical trials using a variety of fluorescent agents. We investigate ABY-029 (anti-EGFR Affibody® molecule labeled with IRDye 800CW) compared with a small-molecule perfusion agent, IRDye 700DX carboxylate, in a panel of soft-tissue sarcomas with varying levels of EGFR expression and vascularization.

METHODS:

Five xenograft soft-tissue sarcoma cell lines were implanted into immunosuppressed mice. ABY-029 and IRDye 700DX were each administered at 4.98 µM. Fluorescence from in vivo and ex vivo (fresh and formalin-fixed) fixed tissues were compared. The performance of three fluorescence imaging systems was assessed for ex vivo tissues.

RESULTS:

ABY-029 is retained longer within tumor tissue and achieves higher tumor-to-background ratios both in vivo and ex vivo than IRDye 700DX. ABY-029 fluorescence is less susceptible to formalin fixation than IRDye 700DX, but both agents have disproportional signal loss in a variety of tissues. The Pearl Impulse provides the highest contrast-to-noise ratio, but all systems have individual advantages.

CONCLUSIONS:

ABY-029 demonstrates promise to assist in wide local excision of soft-tissue sarcomas. Further clinical evaluation of in situ or freshly excised ex vivo tissues using fluorescence imaging systems is warranted.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sarcoma / Proteínas Recombinantes de Fusão / Sondas Moleculares / Receptores ErbB Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sarcoma / Proteínas Recombinantes de Fusão / Sondas Moleculares / Receptores ErbB Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article