Your browser doesn't support javascript.
loading
New UHPLC-QqQ-MS/MS Method for the Rapid and Sensitive Analysis of Ascorbic and Dehydroascorbic Acids in Plant Foods.
Baenas, Nieves; Salar, Francisco J; Domínguez-Perles, Raúl; García-Viguera, Cristina.
Afiliação
  • Baenas N; Institute of Nutritional Medicine, University Medical Center Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Germany. nieves.baenas@uni-luebeck.de.
  • Salar FJ; Phytochemistry and Healthy Food Lab, Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Sciences and Technology, CEBAS-CSIC, University Campus of Espinardo, Edif. 25, 30100 Murcia, Spain. fjsalar@cebas.csic.es.
  • Domínguez-Perles R; Phytochemistry and Healthy Food Lab, Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Sciences and Technology, CEBAS-CSIC, University Campus of Espinardo, Edif. 25, 30100 Murcia, Spain. rdperles@cebas.csic.es.
  • García-Viguera C; Phytochemistry and Healthy Food Lab, Group on Quality, Safety and Bioactivity of Plant Foods, Department of Food Sciences and Technology, CEBAS-CSIC, University Campus of Espinardo, Edif. 25, 30100 Murcia, Spain. cgviguera@cebas.csic.es.
Molecules ; 24(8)2019 Apr 25.
Article em En | MEDLINE | ID: mdl-31027237
ABSTRACT
A new method using ultra high-performance liquid chromatography coupled with triple quadrupole mass spectrometry (UHPLC-QqQ-MS/MS) methodology was developed for the determination of ascorbic acid (AA) and dehydroascorbic acid (DHAA) contents in liquid and solid vegetable samples. The advantages of this method are speed, high sensitivity and practical application. In accordance with these advantages, the present method allows the simultaneous determination of AA and DHAA without previous reduction/derivatization of DHAA and without the use of internal standards in the samples. This is of high interest in routine analysis, providing a simpler sample preparation, as well as enhanced accuracy and robustness. Its validation included selectivity, sensitivity and linearity, precision and accuracy, matrix effect, and recovery. The results showed high selectivity and sensitivity, with calibration curves ranging from 10 to 500 ng mL-1 and from 50 to 500 ng mL-1 for AA and DHAA, respectively. Appropriate dilutions for each sample are necessary to avoid the matrix effect with accepted recoveries.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácido Ascórbico / Cromatografia Líquida de Alta Pressão / Ácido Desidroascórbico / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ácido Ascórbico / Cromatografia Líquida de Alta Pressão / Ácido Desidroascórbico / Espectrometria de Massas em Tandem Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Ano de publicação: 2019 Tipo de documento: Article