Your browser doesn't support javascript.
loading
Real-time kidney graft perfusion monitoring using infrared imaging during pediatric kidney transplantation.
Fernandez, N; Lorenzo, A; Chua, M; Koyle, M A; Farhat, W; Matava, C.
Afiliação
  • Fernandez N; Department of Surgery, Division of Urology, Hospital for SickKids, University of Toronto, Canada; Division of Urology, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogota, Colombia; Department of Urology, Fundacion Santa Fe de Bogota, Colombia. Electronic address: nicolas.fe
  • Lorenzo A; Department of Surgery, Division of Urology, Hospital for SickKids, University of Toronto, Canada.
  • Chua M; Department of Surgery, Division of Urology, Hospital for SickKids, University of Toronto, Canada.
  • Koyle MA; Department of Surgery, Division of Urology, Hospital for SickKids, University of Toronto, Canada.
  • Farhat W; Department of Surgery, Division of Urology, Hospital for SickKids, University of Toronto, Canada.
  • Matava C; Department of Anesthesia, Hospital for SickKids, University of Toronto, Canada.
J Pediatr Urol ; 15(3): 222.e1-222.e7, 2019 May.
Article em En | MEDLINE | ID: mdl-31029559
ABSTRACT

INTRODUCTION:

Ischemia times in kidney transplantation have shown to be predictive for future graft function. Preservation solutions and anticoagulation protocols have improved the management of pediatric kidney transplantation. Nonetheless, there is no current tool for intra-operative graft monitoring. The aim of this project is to present a novel technique for intra-operative real-time assessment of graft perfusion using a non-invasive infrared camera.

METHODS:

Prospectively, the authors included 10 pediatric patients. Surgical procedure followed their institutional protocol. Infrared imaging was captured at graft preparation, vascular anastomosis, unclamping, and at 30 s, 1, 5, and 10 min after unclamping. Analyzed variables included type of transplant, ischemia and procedure times, type of anastomosis, and results of doppler/ultrasound. Postoperative variables included creatinine levels during first 72 h. Any complications were also recorded. Delta analysis was calculated to establish the variation of temperature after unclamping.

RESULTS:

Average age at transplant was 9.9 years. Five cases were living donor transplants. Mean overall ischemia time was 395.6 (SD 64.4 min). Two patients had poor graft perfusion after unclamping. Of those, one had torsion of the arterial anastomosis and the other was a graft from a donor that required cardiopulmonary resuscitation for 45 min. Thermal imaging showed a correlation of 0.318 between graft temperature change and creatinine decrease. Cut-off delta for temperature for good reperfusion was above 0.2 at 1 min

CONCLUSION:

Real-time infrared imaging shows to be a promising option for non-invasive graft perfusion monitoring. Initial results show good correlation between intra-operative temperature changes, graft perfusion, and postoperative graft function.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Perfusão / Circulação Renal / Diagnóstico por Imagem / Monitorização Intraoperatória / Transplante de Rim / Raios Infravermelhos Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Perfusão / Circulação Renal / Diagnóstico por Imagem / Monitorização Intraoperatória / Transplante de Rim / Raios Infravermelhos Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Male Idioma: En Ano de publicação: 2019 Tipo de documento: Article