Your browser doesn't support javascript.
loading
Is MRCP necessary to diagnose pancreas divisum?
Bogveradze, Nino; Hasse, Felix; Mayer, Philipp; Rupp, Christian; Tjaden, Christin; Klauss, Miriam; Kauczor, Hans-Ulrich; Weber, Tim Frederik.
Afiliação
  • Bogveradze N; Department of MRI, Research Institute of Clinical Medicine (Todua Clinic), 13 Tevdore mgvdlis St., 0112, Tbilisi, Georgia.
  • Hasse F; Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, INF 110, 69120, Heidelberg, Germany.
  • Mayer P; Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, INF 110, 69120, Heidelberg, Germany.
  • Rupp C; Department of Gastroenterology, Infectious Diseases, Intoxication, Heidelberg University Hospital, INF 410, 69120, Heidelberg, Germany.
  • Tjaden C; Department of General, Visceral and Transplantation Surgery, Heidelberg University Hospital, INF 110, 69120, Heidelberg, Germany.
  • Klauss M; Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, INF 110, 69120, Heidelberg, Germany.
  • Kauczor HU; Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, INF 110, 69120, Heidelberg, Germany.
  • Weber TF; Department of Diagnostic and Interventional Radiology, Heidelberg University Hospital, INF 110, 69120, Heidelberg, Germany. tim.weber@med.uni-heidelberg.de.
BMC Med Imaging ; 19(1): 33, 2019 04 29.
Article em En | MEDLINE | ID: mdl-31035952
BACKGROUND: The purpose of this study is to compare the performance of three-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) with non-MRCP T2-weighted magnetic resonance imaging (MRI) sequences for diagnosis of pancreas divisum (PD). METHODS: This is a retrospective study of 342 consecutive patients with abdominal MRI including 3D-MRCP. 3D-MRCP was a coronal respiration-navigated T2-weighted sequence with 1.5 mm slice thickness. Non-MRCP T2-weighted sequences were (1) a coronal inversion recovery sequence (TIRM) with 6 mm slice thickness and (2) a transverse single shot turbo spin echo sequence (HASTE) with 4 mm slice thickness. For 3D-MRCP, TIRM, and HASTE, presence of PD and assessment of evaluability were determined in a randomized manner. A consensus read by two radiologists using 3D-MRCP, non-MRCP T2-weighted sequences, and other available imaging sequences served as reference standard for diagnosis of PD. Statistical analysis included performance analysis of 3D-MRCP, TIRM, and HASTE and testing for noninferiority of non-MRCP T2-weighted sequences compared with 3D-MRCP. RESULTS: Thirty-three of 342 patients (9.7%) were diagnosed with PD using the reference standard. Sensitivity/specificity of 3D-MRCP for detecting PD were 81.2%/69.7% (p < 0.001). Sensitivity/specificity of TIRM and HASTE were 92.5%/93.9 and 98.1%/97.0%, respectively (p < 0.001 each). Grouped sensitivity/specificity of non-MRCP T2-weighted sequences were 99.8%/91.0%. Non-MRCP T2-weighted sequences were non-inferior to 3D-MRCP alone for diagnosis of PD. 20.2, 7.3%, and 2.3% of 3D-MRCP, TIRM, and HASTE, respectively, were not evaluable due to motion artifacts or insufficient duct depiction. CONCLUSIONS: Non-MRCP T2-weighted MRI sequences offer high performance for diagnosis of PD and are noninferior to 3D-MRCP alone. TRIAL REGISTRATION: Not applicable.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pâncreas / Colangiopancreatografia por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pâncreas / Colangiopancreatografia por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article