Your browser doesn't support javascript.
loading
Soft x-ray spectroscopic endstation at beamline 08U1A of Shanghai Synchrotron Radiation Facility.
Liu, Haigang; Cao, Jiefeng; Wang, Yong; Chen, Zhenhua; Yu, Huaina; Zhang, Lijuan; Xu, Zijian; Guo, Zhi; Zhang, Xiangzhi; Zhen, Xiangjun; Zou, Ying; Tai, Renzhong.
Afiliação
  • Liu H; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Cao J; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Wang Y; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Chen Z; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Yu H; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Zhang L; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Xu Z; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Guo Z; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Zhang X; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Zhen X; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Zou Y; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
  • Tai R; Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China.
Rev Sci Instrum ; 90(4): 043103, 2019 Apr.
Article em En | MEDLINE | ID: mdl-31042997
ABSTRACT
A spectroscopic endstation with magnetic field, voltage, and low temperature control has been installed and commissioned at the soft X-ray beamline 08U1A of Shanghai Synchrotron Radiation Facility, which can obtain a magnetic field up to ±0.53 T, applied current and bias voltage, and cryogenic temperatures down to 14 K with a Gifford-McMahon cycle cryocooler. The endstation can perform soft X-ray absorption spectroscopy methods including total electron yield, fluorescence yield, and X-ray excited optical luminance. Combined with an elliptically polarized undulator and the in situ conditions, the endstation can effectively perform X-ray magnetic circular and linear dichroism experiments in the soft X-ray range between photon energies of 250 and 2000 eV.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article