Your browser doesn't support javascript.
loading
Interlaboratory Comparison of Hydrogen-Deuterium Exchange Mass Spectrometry Measurements of the Fab Fragment of NISTmAb.
Hudgens, Jeffrey W; Gallagher, Elyssia S; Karageorgos, Ioannis; Anderson, Kyle W; Filliben, James J; Huang, Richard Y-C; Chen, Guodong; Bou-Assaf, George M; Espada, Alfonso; Chalmers, Michael J; Harguindey, Eduardo; Zhang, Hui-Min; Walters, Benjamin T; Zhang, Jennifer; Venable, John; Steckler, Caitlin; Park, Inhee; Brock, Ansgar; Lu, Xiaojun; Pandey, Ratnesh; Chandramohan, Arun; Anand, Ganesh Srinivasan; Nirudodhi, Sasidhar N; Sperry, Justin B; Rouse, Jason C; Carroll, James A; Rand, Kasper D; Leurs, Ulrike; Weis, David D; Al-Naqshabandi, Mohammed A; Hageman, Tyler S; Deredge, Daniel; Wintrode, Patrick L; Papanastasiou, Malvina; Lambris, John D; Li, Sheng; Urata, Sarah.
Afiliação
  • Hudgens JW; Bioprocess Measurement Group, Biomolecular Measurements Division , National Institute of Standards and Technology , Rockville , Maryland 20850 , United States.
  • Gallagher ES; Institute for Bioscience and Biotechnology Research , 9600 Gudelsky Drive , Rockville , Maryland 20850 , United States.
  • Karageorgos I; Bioprocess Measurement Group, Biomolecular Measurements Division , National Institute of Standards and Technology , Rockville , Maryland 20850 , United States.
  • Anderson KW; Institute for Bioscience and Biotechnology Research , 9600 Gudelsky Drive , Rockville , Maryland 20850 , United States.
  • Filliben JJ; Bioprocess Measurement Group, Biomolecular Measurements Division , National Institute of Standards and Technology , Rockville , Maryland 20850 , United States.
  • Huang RY; Institute for Bioscience and Biotechnology Research , 9600 Gudelsky Drive , Rockville , Maryland 20850 , United States.
  • Chen G; Bioprocess Measurement Group, Biomolecular Measurements Division , National Institute of Standards and Technology , Rockville , Maryland 20850 , United States.
  • Bou-Assaf GM; Institute for Bioscience and Biotechnology Research , 9600 Gudelsky Drive , Rockville , Maryland 20850 , United States.
  • Espada A; Statistical Engineering Division , National Institute of Standards and Technology , Gaithersburg , Maryland 20899 , United States.
  • Chalmers MJ; Pharmaceutical Candidate Optimization, Research and Development , Bristol-Myers Squibb Company , Princeton , New Jersey 08540 , United States.
  • Harguindey E; Pharmaceutical Candidate Optimization, Research and Development , Bristol-Myers Squibb Company , Princeton , New Jersey 08540 , United States.
  • Zhang HM; Analytical Development , Biogen Inc. , 225 Binney Street , Cambridge , Massachusetts 02142 , United States.
  • Walters BT; Centro de Investigación Lilly S.A. , 28108 Alcobendas , Spain.
  • Zhang J; Lilly Research Laboratories , Eli Lilly and Company , Indianapolis , Indiana 46285 , United States.
  • Venable J; Centro de Investigación Lilly S.A. , 28108 Alcobendas , Spain.
  • Steckler C; Protein Analytical Chemistry , Genentech, Inc. , 1 DNA Way , South San Francisco , California 94080 , United States.
  • Park I; Protein Analytical Chemistry , Genentech, Inc. , 1 DNA Way , South San Francisco , California 94080 , United States.
  • Brock A; Protein Analytical Chemistry , Genentech, Inc. , 1 DNA Way , South San Francisco , California 94080 , United States.
  • Lu X; Genomics Institute of the Novartis Research Foundation , 10675 John Jay Hopkins Drive , San Diego , California 92121 , United States.
  • Pandey R; Genomics Institute of the Novartis Research Foundation , 10675 John Jay Hopkins Drive , San Diego , California 92121 , United States.
  • Chandramohan A; Joint Center for Structural Genomics , La Jolla , California 92037 , United States.
  • Anand GS; Genomics Institute of the Novartis Research Foundation , 10675 John Jay Hopkins Drive , San Diego , California 92121 , United States.
  • Nirudodhi SN; Genomics Institute of the Novartis Research Foundation , 10675 John Jay Hopkins Drive , San Diego , California 92121 , United States.
  • Sperry JB; MedImmune LLC , One MedImmune Way , Gaithersburg , Maryland 20878 , United States.
  • Rouse JC; MedImmune LLC , One MedImmune Way , Gaithersburg , Maryland 20878 , United States.
  • Carroll JA; Department of Biological Sciences , National University of Singapore , 14, Science Drive 4 , Singapore 117543.
  • Rand KD; Department of Biological Sciences , National University of Singapore , 14, Science Drive 4 , Singapore 117543.
  • Leurs U; Vaccine R&D , Pfizer Inc. , 401 N Middletown Rd , Pearl River, New York 10965 , United States.
  • Weis DD; Analytical R&D , Pfizer Inc. , 700 Chesterfield Parkway West , Chesterfield , Missouri 63017 , United States.
  • Al-Naqshabandi MA; Analytical R&D , Pfizer Inc. , 1 Burtt Road , Andover , Massachusetts 01810 , United States.
  • Hageman TS; Analytical R&D , Pfizer Inc. , 700 Chesterfield Parkway West , Chesterfield , Missouri 63017 , United States.
  • Deredge D; Department of Pharmacy , University of Copenhagen , Universitetsparken 2 , DK-2100 Copenhagen , Denmark.
  • Wintrode PL; Department of Pharmacy , University of Copenhagen , Universitetsparken 2 , DK-2100 Copenhagen , Denmark.
  • Papanastasiou M; Department of Chemistry , University of Kansas , 1567 Irving Hill Road , Lawrence , Kansas 66045 , United States.
  • Lambris JD; Department of Chemistry , University of Kansas , 1567 Irving Hill Road , Lawrence , Kansas 66045 , United States.
  • Li S; Department of General Science , Soran University , Kawa Street , Soran , Kurdistan Region, Iraq.
  • Urata S; Department of Chemistry , University of Kansas , 1567 Irving Hill Road , Lawrence , Kansas 66045 , United States.
Anal Chem ; 91(11): 7336-7345, 2019 06 04.
Article em En | MEDLINE | ID: mdl-31045344
ABSTRACT
Hydrogen-deuterium exchange mass spectrometry (HDX-MS) is an established, powerful tool for investigating protein-ligand interactions, protein folding, and protein dynamics. However, HDX-MS is still an emergent tool for quality control of biopharmaceuticals and for establishing dynamic similarity between a biosimilar and an innovator therapeutic. Because industry will conduct quality control and similarity measurements over a product lifetime and in multiple locations, an understanding of HDX-MS reproducibility is critical. To determine the reproducibility of continuous-labeling, bottom-up HDX-MS measurements, the present interlaboratory comparison project evaluated deuterium uptake data from the Fab fragment of NISTmAb reference material (PDB 5K8A ) from 15 laboratories. Laboratories reported ∼89 800 centroid measurements for 430 proteolytic peptide sequences of the Fab fragment (∼78 900 centroids), giving ∼100% coverage, and ∼10 900 centroid measurements for 77 peptide sequences of the Fc fragment. Nearly half of peptide sequences are unique to the reporting laboratory, and only two sequences are reported by all laboratories. The majority of the laboratories (87%) exhibited centroid mass laboratory repeatability precisions of ⟨ sLab⟩ ≤ (0.15 ± 0.01) Da (1σx̅). All laboratories achieved ⟨sLab⟩ ≤ 0.4 Da. For immersions of protein at THDX = (3.6 to 25) °C and for D2O exchange times of tHDX = (30 s to 4 h) the reproducibility of back-exchange corrected, deuterium uptake measurements for the 15 laboratories is σreproducibility15 Laboratories( tHDX) = (9.0 ± 0.9) % (1σ). A nine laboratory cohort that immersed samples at THDX = 25 °C exhibited reproducibility of σreproducibility25C cohort( tHDX) = (6.5 ± 0.6) % for back-exchange corrected, deuterium uptake measurements.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos Fab das Imunoglobulinas / Espectrometria de Massa com Troca Hidrogênio-Deutério / Anticorpos Monoclonais Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos Fab das Imunoglobulinas / Espectrometria de Massa com Troca Hidrogênio-Deutério / Anticorpos Monoclonais Idioma: En Ano de publicação: 2019 Tipo de documento: Article