Your browser doesn't support javascript.
loading
Detection of unwarranted CT radiation exposure from patient and imaging protocol meta-data using regularized regression.
Chen, Ruidi; Paschalidis, Ioannis Ch; Hatabu, Hiroto; Valtchinov, Vladimir I; Siegelman, Jenifer.
Afiliação
  • Chen R; Department of Biomedical Engineering, Boston University, United States.
  • Paschalidis IC; Department of Electrical and Computer Engineering, Boston University, 8 St. Mary's Street, Boston, MA 02215, USA.
  • Hatabu H; Department of Biomedical Engineering, Boston University, United States.
  • Valtchinov VI; Department of Electrical and Computer Engineering, Boston University, 8 St. Mary's Street, Boston, MA 02215, USA.
  • Siegelman J; Center for Evidence-Based Imaging (CEBI), Brigham and Women's Hospital, United States.
Eur J Radiol Open ; 6: 206-211, 2019.
Article em En | MEDLINE | ID: mdl-31194104
ABSTRACT

BACKGROUND:

Variability in radiation exposure from CT scans can be appropriate and driven by patient features such as body habitus. Quantitative analysis may be performed to discover instances of unwarranted radiation exposure and to reduce the probability of such occurrences in future patient visits. No universal process to perform identification of outliers is widely available, and access to expertise and resources is variable.

OBJECTIVE:

The goal of this study is to develop an automated outlier detection procedure to identify all scans with an unanticipated high radiation exposure, given the characteristics of the patient and the type of the exam. MATERIALS AND

METHODS:

This Institutional Review Board-approved retrospective cohort study was conducted from June 30, 2012 - December 31, 2013 in a quaternary academic medical center. The de-identified dataset contained 28 fields for 189,959 CT exams. We applied the variable selection method Least Absolute Shrinkage and Selection Operator (LASSO) to select important variables for predicting CT radiation dose. We then employed a regression approach that is robust to outliers, to learn from data a predictive model of CT radiation doses given important variables identified by LASSO. Patient visits whose predicted radiation dose was statistically different from the radiation dose actually received were identified as outliers.

RESULTS:

Our methodology identified 1% of CT exams as outliers. The top-5 predictors discovered by LASSO and strongly correlated with radiation dose were Tube Current, kVp, Weight, Width of collimator, and Reference milliampere-seconds. A human expert validation of the outlier detection algorithm has yielded specificity of 0.85 [95% CI 0.78-0.92] and sensitivity of 0.91 [95% CI 0.85-0.97] (PPV = 0.84, NPV = 0.92). These values substantially outperform alternative methods we tested (F1 score 0.88 for our method against 0.51 for the alternatives).

CONCLUSION:

The study developed and tested a novel, automated method for processing CT scanner meta-data to identify CT exams where patients received an unwarranted amount of radiation. Radiation safety and protocol review committees may use this technique to uncover systemic issues and reduce future incidents.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article