Your browser doesn't support javascript.
loading
Defining accelerometer cut-points for different intensity levels in motor-complete spinal cord injury.
Holmlund, Tobias; Ekblom-Bak, Elin; Franzén, Erika; Hultling, Claes; Wahman, Kerstin.
Afiliação
  • Holmlund T; Department of Neurobiology, Care Sciences and Society, Division of Neurogeriatrics, Karolinska Institutet, 171 77, Stockholm, Sweden. Tobias.holmlund@ki.se.
  • Ekblom-Bak E; Rehab Station Stockholm/Spinalis R&D Unit, Frösundaviks allé 4 169 89, Solna, Sweden. Tobias.holmlund@ki.se.
  • Franzén E; Åstrand Laboratory of Work Physiology, The Swedish School of Sport and Health Sciences, Box 5626, 114 86, Stockholm, Sweden.
  • Hultling C; Department of Neurobiology, Care Sciences and Society, Division of Physiotherapy, Karolinska Institutet, 141 83, Stockholm, Sweden.
  • Wahman K; Allied Health Professionals Function, Function Area Occupational Therapy & Physiotherapy, Karolinska University Hospital, 171 76, Stockholm, Sweden.
Spinal Cord ; 58(1): 116-124, 2020 Jan.
Article em En | MEDLINE | ID: mdl-31243318
ABSTRACT
STUDY

DESIGN:

Descriptive.

OBJECTIVE:

The present aim was to define accelerometer cut-point values for wrist-worn accelerometers to identify absolute- and relative-intensity physical activity (PA) levels in people with motor-complete paraplegics (PP) and tetraplegics (TP). SETTINGS Rehabilitation facility in Sweden.

METHODS:

The participants were 26 (19 men, 7 women) with C5-C8, AIS A and B (TP) and 37 (27 men, 10 women) with T7-T12 (PP), AIS A and B. Wrist-worn accelerometer recordings (Actigraph GT3X+) were taken during seven standardized activities. Oxygen consumption was measured, as well as at-rest and peak effort, with indirect calorimetry. Accelerometer cut-points for absolute and relative intensities were defined using ROC-curve analyses.

RESULTS:

The ROC-curve analyses for accelerometer cut-points revealed good-to-excellent accuracy (AUC >0.8), defining cut-points for absolute intensity (2, 3, 4, 5, 6, 7 METs for PP and 2 to 6 METs for TP) and relative intensity (30, 40, 50, 60, 70, and 80% for PP and 40-80% for TP). The cut-points for moderate-to-vigorous physical activity was defined as ≥9515 vector magnitude counts per minute (VMC) for PP and ≥4887 VMC/min for TP.

CONCLUSION:

This study presents cut-points for wrist-worn accelerometers in both PP and TP, which could be used in clinical practice to describe physical activity patterns and time spent at different intensity levels.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Paraplegia / Quadriplegia / Traumatismos da Medula Espinal / Exercício Físico / Acelerometria Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Paraplegia / Quadriplegia / Traumatismos da Medula Espinal / Exercício Físico / Acelerometria Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article