Numerical study on the dynamics of primary cilium in pulsatile flows by the immersed boundary-lattice Boltzmann method.
Cui, Jingyu; Liu, Yang; Fu, Bingmei M.
Afiliação
  • Cui J; Research Centre for Fluid-Structure Interactions, Department of Mechanical Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong.
  • Liu Y; Research Centre for Fluid-Structure Interactions, Department of Mechanical Engineering, The Hong Kong Polytechnic University, Hung Hom, Hong Kong. mmyliu@polyu.edu.hk.
  • Fu BM; Department of Biomedical Engineering, City College of New York, New York City, USA.
Biomech Model Mechanobiol ; 19(1): 21-35, 2020 Feb.
Article em En | MEDLINE | ID: mdl-31256275
ABSTRACT
An explicit immersed boundary-lattice Boltzmann method is applied to numerically investigate the dynamics of primary cilium in pulsatile blood flows with two-way fluid-structure interaction considered. To well characterize the effect of cilium basal body on cilium dynamics, the cilium base is modeled as a nonlinear rotational spring attached to the cilium's basal end as proposed by Resnick (Biophys J 10918-25, 2015. https//doi.org/10.1016/j.bpj.2015.05.031). After several careful validations, the fluid-cilium interaction system is investigated in detail at various pulsatile flow conditions that are characterized by peak Reynolds numbers ([Formula see text]) and Womersley numbers ([Formula see text]). The periodic flapping of primary cilium observed in our simulations is very similar to the in vivo ciliary oscillation captured by O'Connor et al. (Cilia 28, 2013. https//doi.org/10.1186/2046-2530-2-8). The cilium's dynamics is found to be closely related to the [Formula see text] and [Formula see text]. Increase the [Formula see text] or decrease the [Formula see text] bring to an increase in the cilium's flapping amplitude, tip angular speed, basal rotation, and maximum tensile stress. It is also demonstrated that by reducing the [Formula see text] or enhancing the [Formula see text] to a certain level, one can shift the flapping pattern of cilium from its original two-side one to a one-side one, making the stretch only happen on one particular side. During the flapping process, the location of the maximum tensile stress is not always found at the basal region; instead, it is able to propagate from time to time within a certain distance to the base. Due to the obstruction of the primary cilium, the distribution of wall shear stress no longer remains uniform as in the absence of cilia. It oscillates in space with the minimum magnitude which is always found near where the cilium is located. The presence of cilium also reduces the overall level of wall shear stress, especially at the region near the cilium's anchor point.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Numérica Assistida por Computador / Fluxo Pulsátil / Cílios / Modelos Biológicos Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Numérica Assistida por Computador / Fluxo Pulsátil / Cílios / Modelos Biológicos Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article