Your browser doesn't support javascript.
loading
Type IV Cell-Mediated Hypersensitivity Reaction Caused by Titanium Implant Following Double Calcaneal Osteotomy and First Metatarsal-Cuneiform Arthrodesis: A Case Report and Review of the Literature.
Razzante, Mark C; Ehredt, Duane J; Clougherty, Coleman O; Kriger, Stephen J; Menninger, Brennan A; Behan Dionisopoulos, Shontal; Bhakta, Parth J; Bruning, Nicholas G.
Afiliação
  • Razzante MC; Assistant Professor, Department of Podiatric Surgery and Biomechanics, Kent State University College of Medicine, Cleveland, OH. Electronic address: mrazzant@kent.edu.
  • Ehredt DJ; Assistant Professor, Department of Podiatric Surgery and Biomechanics, Kent State University College of Medicine, Cleveland, OH.
  • Clougherty CO; Cleveland Lower Extremity Specialists, Parma, OH.
  • Kriger SJ; Podiatric Surgery Resident, Scripps Mercy Hospital Residency Program, San Diego, CA.
  • Menninger BA; Podiatric Surgery Resident, North Colorado Medical Center Residency Program, Greeley, CO.
  • Behan Dionisopoulos S; Podiatric Surgery Resident, Kaiser Permanente San Francisco Bay Area Residency Program, San Francisco, CA.
  • Bhakta PJ; Podiatric Surgery Resident, Hunt Regional Medical Center Residency Program, Greenville, TX.
  • Bruning NG; Podiatric Surgery Resident, St. Mary Mercy Livonia Residency Program, Livonia, MI.
J Foot Ankle Surg ; 58(5): 974-979, 2019 Sep.
Article em En | MEDLINE | ID: mdl-31266695
Because of their inert character and desired biocompatibility, titanium implants have been universally accepted as safer alternatives to the conventional stainless steel orthopedic implants; however, recent emergence of type IV hypersensitivity reactions to titanium have included eczema, contact dermatitis, a prolonged febrile state, sterile osteonecrosis, and impaired fracture and wound healing. This report presents a patient with postoperative incision dehiscence and devascularization of surfaces in contact with titanium hardware after undergoing a double calcaneal osteotomy and a first metatarsal-cuneiform arthrodesis using titanium alloy implants. Titanium hypersensitivity was confirmed in this case through standard allergy patch testing by a board-certified immunologist. Complete healing occurred after diagnosis of the titanium allergy and hardware explant. To our knowledge, this is one of a few known allergies to titanium implants after foot and ankle surgery.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrodese / Titânio / Ossos do Metatarso / Hipersensibilidade Tardia Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrodese / Titânio / Ossos do Metatarso / Hipersensibilidade Tardia Tipo de estudo: Diagnostic_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article