Your browser doesn't support javascript.
loading
Development of an automated on-line purification HPLC single cell-ICP-MS approach for fast diatom analysis.
Au, Marcus von der; Schwinn, Max; Kuhlmeier, Katharina; Büchel, Claudia; Meermann, Björn.
Afiliação
  • Au MV; Federal Institute for Materials Research and Testing, Division 1.1 - Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489, Berlin, Germany; Federal Institute of Hydrology, Department G2 - Aquatic Chemistry, Am Mainzer Tor 1, 56068, Koblenz, Germany.
  • Schwinn M; Federal Institute of Hydrology, Department G2 - Aquatic Chemistry, Am Mainzer Tor 1, 56068, Koblenz, Germany.
  • Kuhlmeier K; Goethe University Frankfurt, Institute of Molecular Biosciences, Campus Riedberg, Building 210, Max-von-Laue-Str. 9, 60438, Frankfurt am Main, Germany.
  • Büchel C; Goethe University Frankfurt, Institute of Molecular Biosciences, Campus Riedberg, Building 210, Max-von-Laue-Str. 9, 60438, Frankfurt am Main, Germany.
  • Meermann B; Federal Institute for Materials Research and Testing, Division 1.1 - Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489, Berlin, Germany. Electronic address: bjoern.meermann@bam.de.
Anal Chim Acta ; 1077: 87-94, 2019 Oct 24.
Article em En | MEDLINE | ID: mdl-31307725
The most challenging part in performing a single cell ICP-MS (sc-ICP-MS) approach is the sample preparation, in particular the reduction of the ionic background. This step is, in many cases, time-consuming and required for each sample separately. Furthermore, sc-ICP-MS measurements are mostly carried out "manually", given the fact that present systems are not allowing for an automated change of samples. Thus, within this work, we developed an approach based on a HPLC system coupled on-line with sc-ICP-MS via a set of switching valves as well as an in-line filter for automated cell washing. This set-up enables the ionic background removal as well as analysis of single cells completely automated without any manual sample pretreatment. Our approach was applied for the analysis of the single celled diatom species Cyclotella meneghiniana, a marine diatom species, on the basis of 24Mg and facilitates testing in 11 min per sample, requiring only around 10,000 cells in a volume of 10 µL and approx. 10 mL of a 5% MeOH/95% deionized water (v/v) mixture. Even at extremely saline culturing media concentrations (up to 1000 mg L-1 magnesium) our on-line approach worked sufficiently allowing for distinction of ionic and particulate fractions. Furthermore, a set of diatom samples was analyzed completely automated without the need for changing samples manually. So, utilizing this approach enables analyzing a high quantity of samples in a short time and therefore in future the investigation of ecotoxicological effects is simplified for example in terms of metal accumulation by taking biovariability into account.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Diatomáceas Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Diatomáceas Idioma: En Ano de publicação: 2019 Tipo de documento: Article