Your browser doesn't support javascript.
loading
Stimulated grip strength measurement: Validation of a novel method for functional assessment.
Hanwright, Philip J; Rath, Jennifer L; von Guionneau, Nicholas; Harris, Thomas G W; Sarhane, Karim A; Kemp, Stephen W P; Hoke, Ahmet; Cederna, Paul S; Tuffaha, Sami H.
Afiliação
  • Hanwright PJ; Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • Rath JL; Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • von Guionneau N; Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • Harris TGW; Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • Sarhane KA; Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • Kemp SWP; Section of Plastic and Reconstructive Surgery, Department of Surgery, University of Michigan, Ann Arbor, Michigan.
  • Hoke A; Department of Neurology, Johns Hopkins University School of Medicine, Baltimore, Maryland.
  • Cederna PS; Section of Plastic and Reconstructive Surgery, Department of Surgery, University of Michigan, Ann Arbor, Michigan.
  • Tuffaha SH; Department of Plastic and Reconstructive Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
Muscle Nerve ; 60(4): 437-442, 2019 10.
Article em En | MEDLINE | ID: mdl-31325319
BACKGROUND: Reliable measurement of functional recovery is critical in translational peripheral nerve regeneration research. Behavioral functional assessments such as volitional grip strength testing (vGST) are limited by inherent behavioral variability. Isometric tetanic force testing (ITFT) is highly reliable but precludes serial measurements. Combining elements of vGST and ITFT, stimulated grip strength testing (sGST) involves percutaneous median nerve stimulation to elicit maximal tetanic contraction of digital flexors, thereby allowing for consistent measurement of maximal grip strength. METHODS: We measured side-to-side equivalence of force using sGST, vGST, and ITFT to determine relative reliability and repeatability. We also performed weekly force measurements following median nerve repair. RESULTS: sGST demonstrated greater reliability and inter-trial repeatability than vGST and similar reliability to ITFT, with the added benefit of serial measurements. CONCLUSIONS: sGST is a valid method for assessing functional recovery that addresses the limitations of the currently available modalities used in translational peripheral nerve regeneration research.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Força da Mão / Recuperação de Função Fisiológica / Contração Isométrica / Nervo Mediano / Regeneração Nervosa Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Força da Mão / Recuperação de Função Fisiológica / Contração Isométrica / Nervo Mediano / Regeneração Nervosa Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article