Your browser doesn't support javascript.
loading
Radiologic and Clinical Outcomes After Hamstring Anterior Cruciate Ligament Reconstruction Using an Adjustable-Loop Cortical Suspension Device With Retensioning and Knot Tying.
Choi, Nam-Hong; Park, Tae-Hoon; Oh, Whang-Kyun; Victoroff, Brian N.
Afiliação
  • Choi NH; Department of Orthopaedic Surgery, Eulji Medical Center, Seoul, Republic of Korea. Electronic address: cnh2406@yahoo.com.
  • Park TH; Department of Orthopaedic Surgery, Eulji Medical Center, Seoul, Republic of Korea.
  • Oh WK; Department of Orthopaedic Surgery, Eulji Medical Center, Seoul, Republic of Korea.
  • Victoroff BN; Department of Orthopaedic Surgery, Case Western Reserve University, Cleveland, Ohio, U.S.A.
Arthroscopy ; 35(9): 2629-2633, 2019 09.
Article em En | MEDLINE | ID: mdl-31402224
ABSTRACT

PURPOSE:

To report magnetic resonance imaging (MRI) findings and clinical outcomes after anterior cruciate ligament reconstruction using an adjustable-loop device (ALD) with retensioning and knot tying.

METHODS:

The inclusion criteria were patients who underwent hamstring anterior cruciate ligament reconstruction using an ALD with retensioning and knot tying between May and December 2015 and were followed up for a minimum of 2 years. The exclusion criteria were patients with combined ligament injury, revision surgery, or reinjury after reconstruction. After initial tightening of the adjustable loop, retensioning and knot tying were performed and the graft was fixed at the tibia. Multiplanar reformatted images of 3-T MRI scans were obtained on the immediate postoperative day and at 6 months after surgery to measure the gap between the top of the graft and the top of the femoral tunnel (i.e., tunnel-graft gap). Differences in the tunnel-graft gap between the immediate postoperative day and 6 months after surgery (i.e., gap difference) were calculated and correlated with knee stability and functional outcomes.

RESULTS:

Thirty-six patients were enrolled in this study. The mean tunnel-graft gap was 2.1 ± 2.8 mm on the immediate postoperative day and 4.6 ± 3.5 mm at 6 months after surgery (P < .001). The mean gap difference was 2.5 ± 2.0 mm. The mean KT-1000 measurement was 1.5 ± 2.2 mm, and mean Lysholm score and Tegner activity scale score were 93.6 ± 5.5 and 5.6 ± 1.5, respectively. The gap difference correlated negatively with the follow-up Lysholm score (P = .004); however, knee stability and the Tegner activity scale score were not correlated.

CONCLUSIONS:

Although the ALD was secured by retensioning and knot tying, MRI showed that the graft was not fully inserted in some patients and the tunnel-graft gap increased at 6 months' follow-up. The increase in the tunnel-graft gap did not correlate with knee stability or the Tegner activity scale score but correlated negatively with the Lysholm score. LEVEL OF EVIDENCE Level IV, therapeutic case series.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dispositivos de Fixação Ortopédica / Reconstrução do Ligamento Cruzado Anterior / Lesões do Ligamento Cruzado Anterior Tipo de estudo: Etiology_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dispositivos de Fixação Ortopédica / Reconstrução do Ligamento Cruzado Anterior / Lesões do Ligamento Cruzado Anterior Tipo de estudo: Etiology_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article