Your browser doesn't support javascript.
loading
Predictive factors for breast lesion excision system (BLES) accuracy and safety in stereotactic biopsy of suspicious calcifications.
Christou, Alexandra; Koutoulidis, Vassilis; Koulocheri, Dimitra; Nonni, Afrodite; Zografos, Constantinos G; Zografos, George C.
Afiliação
  • Christou A; Brighton and Sussex University Hospital, NHS, Brighton, UK.
  • Koutoulidis V; First Department of Radiology, Areteion Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
  • Koulocheri D; Department of Radiology, Breast Unit Hippokration Hospital, Athens, Greece.
  • Nonni A; Department of Pathology, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
  • Zografos CG; Nikaia General Hospital, Athens, Greece.
  • Zografos GC; Hippokration General Hospital, A' Surgical Clinic, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece.
Breast J ; 26(3): 391-398, 2020 03.
Article em En | MEDLINE | ID: mdl-31448476
AIM: To retrospectively assess the effectiveness and safety of BLES stereotactic biopsy of suspicious calcifications and investigate possible predictive factors for underestimation. METHODS AND MATERIALS: Between January 2014 and January 2016, 400 biopsies of suspicious calcifications were performed in our Department using the BLES stereotactic device. The mean age of our population was 58.5 years (range 39-78 years). The final surgical results were used as gold standard. The effectiveness of the method was statistically evaluated. Mammographic size, grade, molecular type, and presence of comedo type/necrosis were assessed as predictive factors. RESULTS: 90/400 (22.5%) cases were cancers (20% invasive cancers, 80% non-invasive cancers). 38/400 cases were atypical lesions (9.5%). No underestimation was found in atypical lesions that underwent surgery (29/38 cases). Downgrade was achieved in 45.5% of cases (with complete removal in 34.4%), concordance in 43.3%, and upgrade was found in 15.5% of the cases; the initial mammographic size and the grade of the cancers were found to be statistically significant predictive factors. The total complication rate was 8.75%. CONCLUSIONS: Breast lesion excision system is a highly accurate and safe stereotactic biopsy technique of suspicious calcifications with low underestimations and high downgrade/removal rates with the potential to alter the final surgical decision in selected cases.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Carcinoma Intraductal não Infiltrante Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Carcinoma Intraductal não Infiltrante Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article