Your browser doesn't support javascript.
loading
Disposable optical sensor for Al(III) ions determination by coupled colorimetric solid-phase extraction-reflectance spectroscopy in leachates from cookware, antacids and hygienic care products.
Castañeda-Loaiza, V; Díaz-de-Alba, M I; Granado-Castro, M D; Galindo-Riaño, M D; Casanueva-Marenco, M J.
Afiliação
  • Castañeda-Loaiza V; Department of Analytical Chemistry, Institute of Biomolecules (INBIO), Faculty of Sciences, CEI-MAR. University of Cadiz, Campus Rio San Pedro, ES-11510, Puerto Real, Cadiz, Spain.
  • Díaz-de-Alba MI; Department of Analytical Chemistry, Institute of Biomolecules (INBIO), Faculty of Sciences, CEI-MAR. University of Cadiz, Campus Rio San Pedro, ES-11510, Puerto Real, Cadiz, Spain.
  • Granado-Castro MD; Department of Analytical Chemistry, Institute of Biomolecules (INBIO), Faculty of Sciences, CEI-MAR. University of Cadiz, Campus Rio San Pedro, ES-11510, Puerto Real, Cadiz, Spain.
  • Galindo-Riaño MD; Department of Analytical Chemistry, Institute of Biomolecules (INBIO), Faculty of Sciences, CEI-MAR. University of Cadiz, Campus Rio San Pedro, ES-11510, Puerto Real, Cadiz, Spain. Electronic address: dolores.galindo@uca.es.
  • Casanueva-Marenco MJ; Department of Analytical Chemistry, Institute of Biomolecules (INBIO), Faculty of Sciences, CEI-MAR. University of Cadiz, Campus Rio San Pedro, ES-11510, Puerto Real, Cadiz, Spain.
Talanta ; 205: 120102, 2019 Dec 01.
Article em En | MEDLINE | ID: mdl-31450421
ABSTRACT
A disposable and miniaturised optical sensor based on colorimetric solid-phase extraction has been designed using poly(styrene-divinylbenzene) membrane disks modified with the colorimetric reagent pyridoxal salicyloylhydrazone to determine the aluminium concentration in aqueous solutions. The extraction of Al(III) ions by the reagent immobilised onto a disk allows the quantification directly on the adsorbent surface by a miniature portable reflectance spectrometer with an optical fibre at 434 nm. The optimisation of the sensing system was carried out by a fractional factorial design 33-1 considering the extraction pH, amount of ligand immobilised onto the disk and time of immobilisation as experimental factors. The linear dynamic range of the sensor response ranged from 0.18 to 2 mg L-1 Al(III) with a detection limit of 0.18 mg L-1 (n = 10), being the precision of 6.3% for 1 mg L-1 Al(III) (n = 10, confidence level of 95%). The proposed method was successfully applied to the analysis of aluminium in leachates from cookware, antacids and hygienic care products, as contribution to the concern about aluminium as a known systemic toxicant at high doses.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Alumínio Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Alumínio Idioma: En Ano de publicação: 2019 Tipo de documento: Article