Your browser doesn't support javascript.
loading
Differentiation between subcentimeter carcinomas and benign lesions using kinetic parameters derived from ultrafast dynamic contrast-enhanced breast MRI.
Onishi, Natsuko; Sadinski, Meredith; Gibbs, Peter; Gallagher, Katherine M; Hughes, Mary C; Ko, Eun Sook; Dashevsky, Brittany Z; Shanbhag, Dattesh D; Fung, Maggie M; Hunt, Theodore M; Martinez, Danny F; Shukla-Dave, Amita; Morris, Elizabeth A; Sutton, Elizabeth J.
Afiliação
  • Onishi N; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Sadinski M; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Gibbs P; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Gallagher KM; Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Hughes MC; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Ko ES; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Dashevsky BZ; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Shanbhag DD; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Fung MM; Department of Radiology & Biomedical Imaging, University of California, San Francisco, CA, USA.
  • Hunt TM; GE Healthcare, Bangalore, India.
  • Martinez DF; GE Healthcare, New York, NY, USA.
  • Shukla-Dave A; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Morris EA; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
  • Sutton EJ; Breast Imaging Service, Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.
Eur Radiol ; 30(2): 756-766, 2020 Feb.
Article em En | MEDLINE | ID: mdl-31468162
ABSTRACT

OBJECTIVES:

This study aims to evaluate ultrafast DCE-MRI-derived kinetic parameters that reflect contrast agent inflow effects in differentiating between subcentimeter BI-RADS 4-5 breast carcinomas and benign lesions.

METHODS:

We retrospectively reviewed consecutive 3-T MRI performed from February to October 2017, during which ultrafast DCE-MRI was performed as part of a hybrid clinical protocol with conventional DCE-MRI. In total, 301 female patients with 369 biopsy-proven breast lesions were included. Ultrafast DCE-MRI was acquired continuously over approximately 60 s (temporal resolution, 2.7-7.1 s/phase) starting simultaneously with the start of contrast injection. Four ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS], contrast enhancement ratio [CER], bolus arrival time [BAT], and initial area under gadolinium contrast agent concentration [IAUGC]) and one conventional DCE-MRI-derived kinetic parameter (signal enhancement ratio [SER]) were calculated for each lesion. Wilcoxon rank sum test or Fisher's exact test was performed to compare kinetic parameters, volume, diameter, age, and BI-RADS morphological descriptors between subcentimeter carcinomas and benign lesions. Univariate/multivariate logistic regression analyses were performed to determine predictive parameters for subcentimeter carcinomas.

RESULTS:

In total, 125 lesions (26 carcinomas and 99 benign lesions) were identified as BI-RADS 4-5 subcentimeter lesions. Subcentimeter carcinomas demonstrated significantly larger MS and SER and shorter BAT than benign lesions (p = 0.0117, 0.0046, and 0.0102, respectively). MS, BAT, and age were determined as significantly predictive for subcentimeter carcinoma (p = 0.0208, 0.0023, and < 0.0001, respectively).

CONCLUSIONS:

Ultrafast DCE-MRI-derived kinetic parameters may be useful in differentiating subcentimeter BI-RADS 4 and 5 carcinomas from benign lesions. KEY POINTS • Ultrafast DCE-MRI can generate kinetic parameters, effectively differentiating breast carcinomas from benign lesions. • Subcentimeter carcinomas demonstrated significantly larger maximum slope and shorter bolus arrival time than benign lesions. • Maximum slope and bolus arrival time contribute to better management of suspicious subcentimeter breast lesions.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Aumento da Imagem / Meios de Contraste Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Aumento da Imagem / Meios de Contraste Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article