Sequential dual-phase cone-beam CT is able to intra-procedurally predict the one-month treatment outcome of multi-focal HCC, in course of degradable starch microsphere TACE.
Radiol Med
; 124(12): 1212-1219, 2019 Dec.
Article
em En
| MEDLINE
| ID: mdl-31473930
ABSTRACT
OBJECTIVE:
To evaluate the prognostic value of sequential dual-phase CBCT (DP-CBCT) imaging performed during degradable starch microsphere TACE (DSM-TACE) session in predicting the HCC's response to treatment, evaluate with modify response evaluation criteria in solid tumours (mRECIST) at 1-month multi-detector CT (MDCT) follow-up. MATERIALS ANDMETHODS:
Between January and May 2018, 24 patients (68.5 ± 8.5 year [45-85]) with HCC lesions (n = 96 [average 4/patient]) were prospectively enrolled. Imaging assessment included pre-procedural MDCT, intra-procedural DP-CBCT performed before first and second DSM-TACEs and 1-month follow-up MDCT. Lesions' attenuation/pseudo-attenuation was defined as average value measured on ROIs (HU for MDCT; arbitrary unit called HU* for CBCT). Lesions' attenuation modification was correlated with the post-procedural mRECIST criteria at 1-month MDCT.RESULTS:
Eighty-two DSM-TACEs were performed. Lesion's attenuation values were pre-procedural MDCT arterial phase (AP) 107.00 HU (CI 95% 100.00-115.49), venous phase (VP) 85.00 HU (CI 95% 81.13-91.74); and lesion's pseudo-attenuation were first CBCT-AP 305.00 HU* (CI 95% 259.77-354.04), CBCT-VP 155.00 HU* (CI 95% 135.00-163.34). For second CBCT were -AP 210.00 HU* (CI 95% 179.47-228.58), -VP 141.00 HU* (CI 95% 125.47-158.11); and for post-procedural MDCT were -AP 95.00 HU (CI 95% 81.35-102.00), -VP 83.00 HU (CI 95% 78.00-88.00). ROC curve analysis showed that a higher difference pseudo-attenuation between first and second DP-CBCTs is related to treatment response. The optimal cut-off value of the difference between first and second CBCT-APs to predict complete response, objective response (complete + partial response) and overall disease control (objective response + stable disease) were > 206 HU* (sensitivity 80.0%, specificity 81.7%), > 72 HU* (sensitivity 79.5%, specificity 83.0%) and > - 7 HU* (sensitivity 91.6%, specificity 65.4%), respectively.CONCLUSIONS:
DP-CBCT can predict intra-procedurally, by assessing lesion pseudo-attenuation modification, the DSM-TACE 1-month treatment outcome.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Amido
/
Quimioembolização Terapêutica
/
Carcinoma Hepatocelular
/
Tomografia Computadorizada de Feixe Cônico
/
Neoplasias Hepáticas
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2019
Tipo de documento:
Article