Your browser doesn't support javascript.
loading
Standards on Digital Echocardiography: An Israel Heart Society Position Paper Presented by the Israel Working Group on Echocardiography.
Leitman, Marina; Topilsky, Yan; Tyomkin, Vladimir; Carasso, Shemy; Shimoni, Sara; Goland, Sorel; Ben Zekry, Sagit; Sagie, Alik; Cohen, Noah L; Yosefy, Chaim; Beeri, Rоnen.
Afiliação
  • Leitman M; Department of Cardiology, Shamir Medical Center (Assaf Harofeh), Zerifin, Israel.
  • Topilsky Y; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Tyomkin V; Department of Cardiovascular Diseases, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.
  • Carasso S; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
  • Shimoni S; Department of Cardiology, Shamir Medical Center (Assaf Harofeh), Zerifin, Israel.
  • Goland S; Department of Cardiovascular Medicine, Padeh Medical Center, Poriya, Israel.
  • Ben Zekry S; Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
  • Sagie A; Heart Institute, Kaplan Medical Center, Rehovot, Israel.
  • Cohen NL; Hebrew University-Hadassah Medical School, Jerusalem, Israel.
  • Yosefy C; Heart Institute, Kaplan Medical Center, Rehovot, Israel.
  • Beeri R; Hebrew University-Hadassah Medical School, Jerusalem, Israel.
Isr Med Assoc J ; 21(8): 524-527, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31474013
ABSTRACT

BACKGROUND:

The output settings of echocardiographic systems should be set to the full (original) frame rate and lossless compression (e.g., run-length encoding) in order to transmit echocardiographic videos so that they retain their original quality. In addition, monitors and display cards of echocardiography systems and workstations should be able to support an adaptive refresh rate for displaying video at an arbitrary frame rate, including a high frame rate (90+ fps) without dropping frames and preserving the original frame duration. Currently, the only available option for echocardiography monitors is 144-165 Hz (or higher) based on adaptive frame rate G-Sync or FreeSync technology monitors. These monitors should be accompanied by compatible display cards. Echocardiography systems and workstation video playback software should support G-Sync or FreeSync adaptive frame rate technology to display echocardiography videos at their original frame rates without the effects of jitter and frame drops. Echocardiography systems should support an online display of the videos on the workstations during acquisition with the original quality. The requirements for web-based workstations are the same as for desktops workstations. Hospital digital networks should provide transmission and long-term archiving of the echocardiographic videos in their original acquisition quality.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Gravação em Vídeo / Ecocardiografia / Sistemas de Informação em Radiologia Tipo de estudo: Guideline Limite: Humans País como assunto: Asia Idioma: En Ano de publicação: 2019 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Gravação em Vídeo / Ecocardiografia / Sistemas de Informação em Radiologia Tipo de estudo: Guideline Limite: Humans País como assunto: Asia Idioma: En Ano de publicação: 2019 Tipo de documento: Article