Your browser doesn't support javascript.
loading
A simple liquid chromatography coupled with tandem mass spectrometry approach for the simultaneous quantification of thirteen compounds in rats following oral administration of raw and processed Fructus Xanthii: Application in a comparative pharmacokinetic study.
Jiang, Hai; Yang, Liu; Xing, Xudong; Yan, Meiling; Guo, Xinyue; Man, Wenjing; Hou, Ajiao; Yang, Bingyou; Wang, Qiu-Hong; Kuang, Hai-Xue.
Afiliação
  • Jiang H; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Yang L; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Xing X; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Yan M; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Guo X; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Man W; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Hou A; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Yang B; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Wang QH; Key Laboratory of Chinese Materia Medica, Heilongjiang University of Chinese Medicine, Ministry of Education, Harbin, P. R. China.
  • Kuang HX; Guangdong Pharmaceutical University, Guangzhou, P. R. China.
J Sep Sci ; 42(22): 3403-3412, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31513345
ABSTRACT
A simple and sensitive analysis using ultra high performance liquid chromatography with a tandem mass spectrometric system operated in selected reaction monitoring mode was developed for the determination of 11 phenolic acids, atractyloside, and carboxyatractyloside in rat plasma. The two classes of analytes were then separated on a Waters ACQUITY™ UPLC HSS T3 column (50 mm × 2.1 mm, 1.8 µm) using gradient elution with a mobile phase of 0.2% formic acid in water containing 10 mM ammonium acetate and methanol. Detection was accomplished by selected reaction monitoring scanning via an electrospray source operating in negative ionization mode. The calibration curve was linear (R2  = 0.990) over a concentration range of 1.20-3500 ng/mL, while the validated lower limit of quantification was 1.20 ng/mL. The precision varied from 0.84 to 4.62%, and the accuracy varied within ±5%. The method proved robust with sample freezing and thawing and with short- and long-term sample storage. The established method was used for simultaneous quantification and was successfully used for the first time for the pharmacokinetic evaluation of 13 compounds after the intragastric administration of raw and processed Fructus Xanthii in rats. The results indicated that processing affects the absorption and metabolism of Fructus Xanthii extract. Importantly, the results also indicated the importance of processing for the clinical application of traditional Chinese medicine.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Medicamentos de Ervas Chinesas Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Medicamentos de Ervas Chinesas Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article