Your browser doesn't support javascript.
loading
Simultaneous voltammetric determination of Adrenaline and Tyrosine in real samples by neodymium oxide nanoparticles grafted graphene.
Biswas, Sudip; Naskar, Hemanta; Pradhan, Susmita; Wang, Yang; Bandyopadhyay, Rajib; Pramanik, Panchanan.
Afiliação
  • Biswas S; College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou, Jiangsu, 225002, China. Electronic address: sudipbiswas65@gmail.com.
  • Naskar H; Department of Instrumentation & Electronics Engineering, Jadavpur University Salt Lake Campus, Kolkata, 700098, India.
  • Pradhan S; Department of Instrumentation Science, Jadavpur University, Kolkata, 700032, India.
  • Wang Y; College of Chemistry & Chemical Engineering, Yangzhou University, Yangzhou, Jiangsu, 225002, China. Electronic address: wangyzu@126.com.
  • Bandyopadhyay R; Department of Instrumentation & Electronics Engineering, Jadavpur University Salt Lake Campus, Kolkata, 700098, India; Laboratory of Artificial Sensory Systems, ITMO University, Saint Petersburg, 197101, Russia.
  • Pramanik P; Department of Chemistry and Nanoscience, GLA University, Mathura, 281 406, India.
Talanta ; 206: 120176, 2020 Jan 01.
Article em En | MEDLINE | ID: mdl-31514900
ABSTRACT
Nd2O3 nanoparticle grafted graphene nanocomposite (NOGG) was synthesized by sonochemical treatment of an ethanolic dispersion of Nd2O3 nanoparticle and graphene. All the synthesized materials were characterized by XRD, FESEM, TEM, and BET. The NOGG has a high specific surface area (272 m2g-1) with narrowly distributed pores with diameter centered at 2.8, 6.0 and 7.50 nm. A composite paste electrode of 11 (w/w) NOGG and graphite was showed better electrochemical properties. The NOGG/GP electrode showed all around better electrocatalytic activity towards Adrenaline (AD) and Tyrosine (TY) than TRG/GP and bare GP electrode. According to cyclic voltammograms, AD and TY oxidized irreversibly through adsorption control process. DPV peak currents were measured at 378 ±â€¯15 mV and 787 ±â€¯15 mV for determination AD and TY respectively using the NOGG/GP electrode as the peak intensities were highest at those potentials. Under the optimized experimental condition, the determination ranges for AD and TY showed two linear ranges, those were 0.1-5-130 µM and 0.1-3-120 µM, respectively. A detection limit of AD and TY was measured (m-LOD) to be 50 nM and 40 nM, respectively. The modified electrode was reproducible, selective, highly sensitive and also employed for analysis of AD and TY in biological and pharmaceutical samples with excellent recovery.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article