Your browser doesn't support javascript.
loading
A nurse-led implantable loop recorder service is safe and cost effective.
Lim, Wei Yao; Papageorgiou, Nikolaos; Sukumar, Shivasankar M; Alexiou, Sophia; Srinivasan, Neil T; Monkhouse, Christopher; Daw, Holly; Caldeira, Helder; Harvie, Helen; Kuriakose, Jincymol; Baca, Marco; Ahsan, Syed Y; Chow, Anthony W; Hunter, Ross J; Finlay, Malcolm; Lambiase, Pier D; Schilling, Richard J; Earley, Mark J; Providencia, Rui.
Afiliação
  • Lim WY; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Papageorgiou N; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Sukumar SM; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Alexiou S; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Srinivasan NT; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Monkhouse C; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Daw H; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Caldeira H; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Harvie H; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Kuriakose J; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Baca M; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Ahsan SY; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Chow AW; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Hunter RJ; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Finlay M; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Lambiase PD; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Schilling RJ; Institute of Cardiovascular Science, University College of London, London, United Kingdom.
  • Earley MJ; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
  • Providencia R; Barts Heart Centre - Electrophysiology Department, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.
J Cardiovasc Electrophysiol ; 30(12): 2900-2906, 2019 12.
Article em En | MEDLINE | ID: mdl-31578806
ABSTRACT

INTRODUCTION:

Implantable loop recorders (ILR) are predominantly implanted by cardiologists in the catheter laboratory. We developed a nurse-delivered service for the implantation of LINQ (Medtronic; Minnesota) ILRs in the outpatient setting. This study compared the safety and cost-effectiveness of the introduction of this nurse-delivered ILR service with contemporaneous physician-led procedures.

METHODS:

Consecutive patients undergoing an ILR at our institution between 1st July 2016 and 4th June 2018 were included. Data were prospectively entered into a computerized database, which was retrospectively analyzed.

RESULTS:

A total of 475 patients underwent ILR implantation, 271 (57%) of these were implanted by physicians in the catheter laboratory and 204 (43%) by nurses in the outpatient setting. Six complications occurred in physician-implants and two in nurse-implants (P = .3). Procedural time for physician-implants (13.4 ± 8.0 minutes) and nurse-implants (14.2 ± 10.1 minutes) were comparable (P = .98). The procedural cost was estimated as £576.02 for physician-implants against £279.95 with nurse-implants, equating to a 57.3% cost reduction. In our center, the total cost of ILR implantation in the catheter laboratory by physicians was £10 513.13 p.a. vs £6661.55 p.a. with a nurse-delivered model. When overheads for running, cleaning, and maintaining were accounted for, we estimated a saving of £68 685.75 was performed by moving to a nurse-delivered model for ILR implants. Over 133 catheter laboratory and implanting physician hours were saved and utilized for other more complex procedures.

CONCLUSION:

ILR implantation in the outpatient setting by suitably trained nurses is safe and leads to significant financial savings.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Papel do Médico / Custos de Cuidados de Saúde / Monitorização Ambulatorial / Papel do Profissional de Enfermagem / Tecnologia de Sensoriamento Remoto / Assistência Ambulatorial Tipo de estudo: Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Papel do Médico / Custos de Cuidados de Saúde / Monitorização Ambulatorial / Papel do Profissional de Enfermagem / Tecnologia de Sensoriamento Remoto / Assistência Ambulatorial Tipo de estudo: Health_economic_evaluation / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article