Your browser doesn't support javascript.
loading
High-Throughput Bioassays using "Dip-and-Go" Multiplexed Electrospray Mass Spectrometry.
Wei, Zhenwei; Xie, Zhuoer; Kuvelkar, Reshma; Shah, Vinit; Bateman, Kevin; McLaren, David G; Cooks, R Graham.
Afiliação
  • Wei Z; Aston Labs, Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47906-1393, USA.
  • Xie Z; Aston Labs, Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47906-1393, USA.
  • Kuvelkar R; Merck & Co., Inc., 2000 Galloping Hill Road, Kenilworth, NJ, 07033, USA.
  • Shah V; Merck & Co., Inc., 2000 Galloping Hill Road, Kenilworth, NJ, 07033, USA.
  • Bateman K; Merck & Co., Inc., 2000 Galloping Hill Road, Kenilworth, NJ, 07033, USA.
  • McLaren DG; Merck & Co., Inc., 2000 Galloping Hill Road, Kenilworth, NJ, 07033, USA.
  • Cooks RG; Aston Labs, Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN, 47906-1393, USA.
Angew Chem Int Ed Engl ; 58(49): 17594-17598, 2019 12 02.
Article em En | MEDLINE | ID: mdl-31589796
ABSTRACT
A multiplexed system based on inductive nanoelectrospray mass spectrometry (nESI-MS) has been developed for high-throughput screening (HTS) bioassays. This system combines inductive nESI and field amplification micro-electrophoresis to achieve a "dip-and-go" sample loading and purification strategy that enables nESI-MS based HTS assays in 96-well microtiter plates. The combination of inductive nESI and micro-electrophoresis makes it possible to perform efficient in situ separations and clean-up of biological samples. The sensitivity of the system is such that quantitative analysis of peptides from 1-10 000 nm can be performed in a biological matrix. A prototype of the automation system has been developed to handle 12 samples (one row of a microtiter plate) at a time. The sample loading and electrophoretic clean-up of biosamples can be done in parallel within 20 s followed by MS analysis at a rate of 1.3 to 3.5 s per sample. The system was used successfully for the quantitative analysis of BACE1-catalyzed peptide hydrolysis, a prototypical HTS assay of relevance to drug discovery. IC50 values for this system were in agreement with LC-MS but recorded in times more than an order of magnitude shorter.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Peptídeos / Secretases da Proteína Precursora do Amiloide / Ensaios de Triagem em Larga Escala Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Peptídeos / Secretases da Proteína Precursora do Amiloide / Ensaios de Triagem em Larga Escala Idioma: En Ano de publicação: 2019 Tipo de documento: Article