Your browser doesn't support javascript.
loading
Rapid Quantitation of 25-Hydroxyvitamin D2 and D3 in Human Serum Using Liquid Chromatography/Drift Tube Ion Mobility-Mass Spectrometry.
Oranzi, Nicholas R; Lei, Jiajun; Kemperman, Robin H J; Chouinard, Christopher D; Holmquist, Brett; Garrett, Timothy J; Yost, Richard A.
Afiliação
  • Oranzi NR; Department of Chemistry , University of Florida , P.O. Box 117200, Gainesville , Florida 32611 , United States.
  • Lei J; Department of Chemistry , University of Florida , P.O. Box 117200, Gainesville , Florida 32611 , United States.
  • Kemperman RHJ; Department of Chemistry , University of Florida , P.O. Box 117200, Gainesville , Florida 32611 , United States.
  • Chouinard CD; Department of Biomedical and Chemical Engineering and Sciences , Florida Institute of Technology , Melbourne , Florida 32901 , United States.
  • Holmquist B; LabCorp , Burlington , North Carolina 27216 , United States.
  • Garrett TJ; Department of Pathology , University of Florida , Gainesville , Florida 32610 , United States.
  • Yost RA; Department of Chemistry , University of Florida , P.O. Box 117200, Gainesville , Florida 32611 , United States.
Anal Chem ; 91(21): 13555-13561, 2019 11 05.
Article em En | MEDLINE | ID: mdl-31592654
Ion mobility was integrated with liquid chromatography/high resolution mass spectrometry (LC/IM-HRMS) to quantify 25-hydroxyvitamin D (25OHD) in human serum. It has previously been shown that 25OHD adopts two gas-phase conformations which are resolved using ion mobility; in contrast, the inactive epimer, 3-epi-25-hydroxyvitamin D (epi25OHD), only adopts one. Interference from epi25OHD was eliminated by filtering the chromatogram to retain the drift time that corresponds to the unique gas-phase conformation of 25OHD. Although ion mobility separates the epimers, some chromatography is required to separate compounds which interfere with ionization or fall at the same nominal m/z. Standards were prepared in 4% albumin solutions and compared against commercial serum quality controls. Standards and quality controls were analyzed and validated using a 2 min LC/IM-MS method. 25-Hydroxyvitamin D3 and D2 were quantified over the range between 2 and 500 ng/mL with bias and precision within 15%. When epi25OHD was spiked into quality control samples, no significant bias was introduced, and analysis of 30 patient samples shows good agreement between this LC/IM-MS and traditional LC/MS/MS methods. This work shows that ion mobility can be incorporated with liquid chromatography and mass spectrometry for rapid quantitation of 25OHD in human serum.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Calcifediol / 25-Hidroxivitamina D 2 / Cromatografia Líquida / Espectrometria de Massas em Tandem / Espectrometria de Mobilidade Iônica Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Calcifediol / 25-Hidroxivitamina D 2 / Cromatografia Líquida / Espectrometria de Massas em Tandem / Espectrometria de Mobilidade Iônica Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article