Your browser doesn't support javascript.
loading
On-line in-tube solid phase microextraction coupled to capillary liquid chromatography-diode array detection for the analysis of caffeine and its metabolites in small amounts of biological samples.
Ponce-Rodríguez, H D; García-Robles, A A; Sáenz-González, P; Verdú-Andrés, J; Campíns-Falcó, P.
Afiliação
  • Ponce-Rodríguez HD; MINTOTA Research Group, Departament de Química Analítica. Facultat de Química. Universitat de València. c/Dr., Moliner 50, 46100, Burjassot, València, Spain; Departamento de Control Químico, Facultad de Química y Farmacia, Universidad Nacional Autónoma de Honduras, Ciudad Universitaria, Tegucigalpa,
  • García-Robles AA; Neonatal Research Unit. Division of Neonatology. Hospital, Universitari i Politècnic la Fe. Avd., Fernando Abril Martorell 106, 46026, València, Spain.
  • Sáenz-González P; Neonatal Research Unit. Division of Neonatology. Hospital, Universitari i Politècnic la Fe. Avd., Fernando Abril Martorell 106, 46026, València, Spain.
  • Verdú-Andrés J; MINTOTA Research Group, Departament de Química Analítica. Facultat de Química. Universitat de València. c/Dr., Moliner 50, 46100, Burjassot, València, Spain. Electronic address: jorge.verdu@uv.es.
  • Campíns-Falcó P; MINTOTA Research Group, Departament de Química Analítica. Facultat de Química. Universitat de València. c/Dr., Moliner 50, 46100, Burjassot, València, Spain.
J Pharm Biomed Anal ; 178: 112914, 2020 Jan 30.
Article em En | MEDLINE | ID: mdl-31610396
ABSTRACT
In-tube solid phase microextraction (IT-SPME) coupled on-line to capillary liquid chromatography with diode array detection provides a simple and fast analytical methodology for the simultaneous quantitation of caffeine and its three primary metabolites (theobromine, paraxanthine and theophylline) in micro samples of serum, saliva and urine matrices. The sample amount required for one analysis was only 2.5 µL of saliva, 6.25 µL of serum or 40 µL of urine, a requirement for its implementation in a hospital laboratory for preterm newborns, where sample availability is a major problem. In standard conditions, 25 µL of diluted saliva or serum (or 100 µL of urine) were processed by IT-SPME in 30 cm of commercially available capillary GC column coated with ZB-FFAP (100% nitroterephthalic modified polyethylene glycol). The retained compounds were desorbed from the IT-SPME capillary by the mobile phase (a gradient mixture of water and methanol) and the separation was carried out in a C18 column (150 mm × 0.5 mm i.d., 5 µm particle size). Analytes eluted before 14 min, at a flow rate of 15 µL min-1, and were detected by absorbance at 275 nm. The calibration graphs presented good linearity (R2 > 0.99), without the presence of matrix effect, and recoveries between 84 and 112% were obtained. Limits of detection (S/N = 3) were 0.1 µg·mL-1 in serum and 0.5 µg·mL-1 in saliva and urine samples, for all compounds, and the intra- and inter-day variation coefficients (n = 3) were between 3 and 17%. Analytical figures of merit were similar to those proposed by other methodologies, but using lower sample volume and a faster and simpler sample treatment and analysis. Paired samples of serum and saliva from preterm newborns treated with caffeine at the pediatric intensive care unit were analyzed by the method, with statistically equivalent results for caffeine concentrations.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cafeína Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cafeína Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article