Your browser doesn't support javascript.
loading
Protein precipitation method for determination of clobazam and N-desmethylclobazam in human plasma by LC-MS/MS.
Mikayelyan, Astghik; Aleksanyan, Armine; Sargsyan, Mariam; Gevorgyan, Arpine; Zakaryan, Hasmik; Harutyunyan, Armen; Zhamharyan, Lusine; Armoudjian, Yeghig; Margaryan, Tigran.
Afiliação
  • Mikayelyan A; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Aleksanyan A; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Sargsyan M; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Gevorgyan A; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Zakaryan H; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Harutyunyan A; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Zhamharyan L; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Armoudjian Y; DarmanTest Laboratories LLC, Yerevan, Armenia.
  • Margaryan T; DarmanTest Laboratories LLC, Yerevan, Armenia.
Biomed Chromatogr ; 34(1): e4710, 2020 Jan.
Article em En | MEDLINE | ID: mdl-31630425
A protein precipitation method for the determination of clobazam (CLB) and its major active metabolite N-desmethylclobazam (N-CLB) in human plasma by liquid chromatography tandem mass spectrometry (LC-MS/MS) was established. CLB and N-CLB were extracted from human plasma samples by protein precipitation with methanol. Analyte separation was done using a Phenomenex Kinetex™ Biphenyl (50 × 2.1 mm, 1.7 µm) column using isocratic elution with a mobile phase of 5 mm ammonium formate with 0.01% ammonium hydroxide (40%) and methanol (60%) at a flow rate of 0.4 mL/min and an injection volume of 10 µL. The detection was performed on a triple quadrupole mass spectrometer in multiple reaction monitoring mode to monitor the precursor-to-product ion transitions of m/z 301.1 → 259.0, 306.0 → 263.9 for CLB and CLB-D5 and 287.0 → 245.0, 292.0 → 250.0 for N-CLB and N-CLB-D5 in positive electrospray ionization mode, respectively. The method was validated over a concentration range of 2.0-750 ng/mL for CLB and 0.7-200 ng/mL for N-CLB on SCIEX Triple Quad 4500 MS System. Total run time was 5 min. This method has been designed for bioequivalence study for formulations containing 20 mg of CLB.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Benzodiazepinas / Cromatografia Líquida / Espectrometria de Massas em Tandem / Clobazam Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Benzodiazepinas / Cromatografia Líquida / Espectrometria de Massas em Tandem / Clobazam Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article