Your browser doesn't support javascript.
loading
Enhancing the accuracy of measurement of small molecule organic biomarkers.
Teo, Tang Lin; Lippa, Katrice A; Mackay, Lindsey; Yong, Sharon; Liu, Qinde; Camara, Johanna E; Delatour, Vincent; Lee, Tong Kooi; Lalere, Béatrice; O' Connor, Gavin; Henrion, André; Kato, Megumi; Numata, Masahiko; Kwon, Ha-Jeong; Jeong, Ji-Seon; Xu, Bei; Song, Dewei; Nammoonnoy, Jintana; Wollinger, Wagner.
Afiliação
  • Teo TL; Chemical Metrology Laboratory, Applied Sciences Group, Health Science Authority (HSA), 1 Science Park Road, The Capricorn, Science Park II, Singapore, 117528, Singapore. Teo_Tang_Lin@hsa.gov.sg.
  • Lippa KA; National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD, 20899, USA.
  • Mackay L; National Measurement Institute Australia (NMIA), 105 Delhi Rd, North Ryde, NSW, 2113, Australia.
  • Yong S; Chemical Metrology Laboratory, Applied Sciences Group, Health Science Authority (HSA), 1 Science Park Road, The Capricorn, Science Park II, Singapore, 117528, Singapore.
  • Liu Q; Chemical Metrology Laboratory, Applied Sciences Group, Health Science Authority (HSA), 1 Science Park Road, The Capricorn, Science Park II, Singapore, 117528, Singapore.
  • Camara JE; National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD, 20899, USA.
  • Delatour V; Laboratoire National De Métrologie Et D'essais (LNE), 1 Rue Gaston Boissier, 75015, Paris, France.
  • Lee TK; Chemical Metrology Laboratory, Applied Sciences Group, Health Science Authority (HSA), 1 Science Park Road, The Capricorn, Science Park II, Singapore, 117528, Singapore.
  • Lalere B; Laboratoire National De Métrologie Et D'essais (LNE), 1 Rue Gaston Boissier, 75015, Paris, France.
  • O' Connor G; Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116, Braunschweig, Germany.
  • Henrion A; Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116, Braunschweig, Germany.
  • Kato M; National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan.
  • Numata M; National Metrology Institute of Japan (NMIJ), National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Umezono, Tsukuba, Ibaraki, 305-8563, Japan.
  • Kwon HJ; Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.
  • Jeong JS; Korea Research Institute of Standards and Science (KRISS), 267 Gajeong-ro, Yuseong-gu, Daejeon, 34113, Republic of Korea.
  • Xu B; National Institute of Metrology, China (NIM), No.18, Bei San Huang Dong Lu, Chaoyang District, Beijing, 100029, China.
  • Song D; National Institute of Metrology, China (NIM), No.18, Bei San Huang Dong Lu, Chaoyang District, Beijing, 100029, China.
  • Nammoonnoy J; National Institute of Metrology, Thailand (NIMT), Technopolis Campus, 3/4-5 Moo 3, Klong 5, Klong Luang, Pathumthani, 12120, Thailand.
  • Wollinger W; Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), 50 N Sra das Gracas, Duque de Caxias, Rio de Janeiro, 25250-020, Brazil.
Anal Bioanal Chem ; 411(28): 7341-7355, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31667564
ABSTRACT
Over two decades, the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance Metrology in Chemistry and Biology (CCQM) has organized a number of comparisons for clinically relevant small molecule organic biomarkers. The aim of the OAWG community is to be part of the coordinated international movement towards accuracy and comparability of clinical measurements that will, in turn, minimize the wastage of repeat testing and unnecessary therapy to create a sustainable healthcare industry. International and regional directives/requirements on metrological traceability of calibrators and control materials are in place. Metrology institutes worldwide maintain infrastructure for the practical realization of metrological traceability and demonstrate the equivalence of their measurement capabilities through participation in key comparisons organized under the auspices of the CCQM. These institutes provide certified reference materials, as well as other dedicated value-assignment services benefiting the in-vitro diagnostic (IVD) industry, reference (calibration) laboratories and the clinical chemistry laboratories. The roles of these services in supporting national, regional, and international activities to ensure the metrological traceability of clinical chemistry measurements are described. Graphical abstract.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Orgânicos / Biomarcadores / Bibliotecas de Moléculas Pequenas Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos Orgânicos / Biomarcadores / Bibliotecas de Moléculas Pequenas Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article