Your browser doesn't support javascript.
loading
Corrosion resistance of coupled sandblasted, large-grit, acid-etched (SLA) and anodized Ti implant surfaces in synthetic saliva.
Al Otaibi, Ala'a; Sherif, El-Sayed M; Al-Rifaiy, Mohammed Q; Zinelis, Spiros; Al Jabbari, Youssef S.
Afiliação
  • Al Otaibi A; Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.
  • Sherif EM; Department of Prosthetic Dental Science, College of Dentistry King Saud University Riyadh Saudi Arabia.
  • Al-Rifaiy MQ; Dental Biomaterials Research and Development Chair, College of Dentistry King Saud University Riyadh Saudi Arabia.
  • Zinelis S; Center of Excellence for Research in Engineering Materials (CEREM) King Saud University Riyadh Saudi Arabia.
  • Al Jabbari YS; Electrochemistry and Corrosion Laboratory, Department of Physical Chemistry National Research Centre (NRC) Cairo Egypt.
Clin Exp Dent Res ; 5(5): 452-459, 2019 10.
Article em En | MEDLINE | ID: mdl-31687177

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Saliva Artificial / Titânio / Teste de Materiais / Cromo / Cobalto / Ligas Dentárias Tipo de estudo: Qualitative_research Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Próteses e Implantes / Saliva Artificial / Titânio / Teste de Materiais / Cromo / Cobalto / Ligas Dentárias Tipo de estudo: Qualitative_research Limite: Humans Idioma: En Ano de publicação: 2019 Tipo de documento: Article