Your browser doesn't support javascript.
loading
Development and Optimization of an External-Membrane Introduction Photoionization Mass Spectrometer for the Fast Analysis of (Polycyclic)Aromatic Compounds in Environmental and Process Waters.
Gehm, Christian; Streibel, Thorsten; Ehlert, Sven; Schulz-Bull, Detlef; Zimmermann, Ralf.
Afiliação
  • Gehm C; Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, Institute of Chemistry , University of Rostock , Dr.-Lorenz-Weg 2 , 18059 Rostock , Germany.
  • Streibel T; Joint Mass Spectrometry Centre, Chair of Analytical Chemistry, Institute of Chemistry , University of Rostock , Dr.-Lorenz-Weg 2 , 18059 Rostock , Germany.
  • Ehlert S; Joint Mass Spectrometry Centre, Cooperation Group Comprehensive Molecular Analytics, Institute of Ecological Chemistry , Helmholtz Zentrum München-German Research Center of Environmental Health (GmbH) , Ingolstädter Landstrasse 1 , 85764 Neuherberg , Germany.
  • Schulz-Bull D; Photonion GmbH , Hagenower Strasse 73 , 19061 Schwerin , Germany.
  • Zimmermann R; Leibniz-Institute for Baltic Sea Research Warnemünde , Seestraße 15 , 18119 Rostock-Warnemünde , Germany.
Anal Chem ; 91(24): 15547-15554, 2019 12 17.
Article em En | MEDLINE | ID: mdl-31735029
ABSTRACT
The development of sensitive analytical techniques for the real-time detection of aromatic hydrocarbons (AHs) and polycyclic aromatic hydrocarbons (PAHs) is of high importance, because of their impact on human health and the environment. A promising approach, regarding to direct determination of (P)AHs in aqueous samples, is resonance-enhanced multiphoton ionization (REMPI) coupled to external-membrane introduction mass spectrometry (eMIMS). In eMIMS, analytes are extracted from the water phase into the gas phase, which is supplied to the MS by using an external semipermeable membrane setup. As a result, no laborious enrichment techniques are needed. With REMPI, ions are formed by the subsequent absorption of two photons via an excited molecular state. The unique ionization scheme of REMPI provides selective and sensitive detection of (P)AHs. When combining the capabilities of REMPI and MIMS, direct measurements of sub-µg/L concentrations of small (polycyclic)aromatic compounds are feasible. In this study, we present an external sheet membrane probe (ESMP) for the determination of selected (polycyclic)aromatic species in water samples by using REMPI time-of-flight mass spectrometry (REMPI-TOFMS). This inlet design shows promising results with respect to the direct analysis of (P)AHs in aquatic environments. With this early stage system, concentrations down to tens of ng/L for selected small (polycyclic)aromatic compounds are accessible within minutes without any sample preparation.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article