Your browser doesn't support javascript.
loading
Experimental Validation of Slip-Forming Using Ultrasonic Sensors.
Yoon, Hyejin; Kim, Young Jin; Chin, Won Jong; Kang, Jun Won; Koh, Hyun-Moo.
Afiliação
  • Yoon H; Seismic Safety Research Center, Korea Institute of Civil Engineering and Building Technology, 283 Goyangdae-ro, Ilsanseo-gu, Goyang-si, Gyeonggi-do 10223, Korea.
  • Kim YJ; Seismic Safety Research Center, Korea Institute of Civil Engineering and Building Technology, 283 Goyangdae-ro, Ilsanseo-gu, Goyang-si, Gyeonggi-do 10223, Korea.
  • Chin WJ; Seismic Safety Research Center, Korea Institute of Civil Engineering and Building Technology, 283 Goyangdae-ro, Ilsanseo-gu, Goyang-si, Gyeonggi-do 10223, Korea.
  • Kang JW; Department of Civil Engineering, Hongik University, 94 Wausan-ro, Mapo-gu, Seoul 04066, Korea.
  • Koh HM; Department of Civil and Environmental Engineering, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul 08826, Korea.
Sensors (Basel) ; 19(22)2019 Nov 19.
Article em En | MEDLINE | ID: mdl-31752423
ABSTRACT
Slip-forming in concrete construction enables the continuous placement of concrete using a climbing form, the efficiency of which depends on appropriate slip-up timing. This implies the importance of knowing accurately the development of concrete strength over time, which has been assessed manually to date in construction fields. This paper presents a method for automating the slip-forming process by determining the optimal slip-up time using the in-situ strength of concrete. The strength of concrete is evaluated by a formula relating the strength to the surface wave velocity measured with ultrasonic sensors. Specifically, this study validates the applicability of the slip-form system with ultrasonic sensors for continuously monitoring the hardening of concrete through its application in several construction sites. To this end, a slip-form system with a pair of ultrasonic modules at the bottom of the panel was tested and the time variation of surface wave velocity in the concrete material was monitored during the slip-forming process. The results show that the proposed method can provide the optimal slip-up time of the form to automate the slip-forming process. This approach is expected to apply to other construction technologies that required the continuous monitoring of concrete strength for construction efficiency as well as quality maintenance.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article