Your browser doesn't support javascript.
loading
Endometrial thickness cut-off value by transvaginal ultrasonography for screening of endometrial pathology in premenopausal and postmenopausal women.
Park, Yu Ran; Lee, Shin Wha; Kim, Yeongsin; Bae, In Young; Kim, Hong-Kyu; Choe, Jaewon; Kim, Yong-Man.
Afiliação
  • Park YR; Health Screening and Promotion Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Lee SW; Department of Obstetrics and Gynecology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Kim Y; Health Screening and Promotion Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Bae IY; Health Screening and Promotion Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Kim HK; Health Screening and Promotion Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Choe J; Health Screening and Promotion Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
  • Kim YM; Department of Obstetrics and Gynecology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea.
Obstet Gynecol Sci ; 62(6): 445-453, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31777741
ABSTRACT

OBJECTIVE:

To assess the clinical usefulness and diagnostic accuracy of ultrasonographic measurement of endometrial thickness (ET) in women with endometrial hyperplasia or cancer (EH+).

METHODS:

This retrospective cohort study included 29,995 consecutive women who underwent transvaginal ultrasonography (TVS) for an incidental finding of a thickened endometrium at the health screening and promotion center at Asan Medical Center between 2006 and 2010. Among 959 patients with endometrial abnormalities, 92 patients were included in this study. A total of 867 patients were excluded 416 were lost to follow-up; 263 did not undergo endometrial biopsy; 155 had endometrial polyps; 17 had submucosal myomas; and 16 had insufficient tissue samples. Endometrial histology was the reference standard for calculating accuracy.

RESULTS:

Of the 92 patients, 78 (84.8%) had normal pathology, while 14 (15.2%) had endometrial pathology (EH+), including 5 patients (35.7%) with simple hyperplasia without atypia, 3 (21.4%) with complex hyperplasia, and 6 (42.9%) with endometrial carcinoma, all stage Ia. The area under the receiver-operating characteristic curve was 0.75 (95% confidence interval [CI], 0.593-0.906). The cut-off value for ET was 8 mm, indicating that TVS ET had a fair accuracy in diagnosing carcinoma, had a sensitivity of 100% (95% CI, 62.9-100.0%) and a specificity of 24.3% (95% CI, 15.2-36.3%).

CONCLUSION:

TVS is useful for detecting EH+, with a cut-off value for ET of 8 mm having a high sensitivity for detecting endometrial pathologies and the ability to identify women highly unlikely to have EH+, thereby avoiding more invasive endometrial biopsy.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Screening_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Screening_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article