Your browser doesn't support javascript.
loading
Biocompatibility of bioabsorbable Mg-Ca alloys with rare earth elements addition.
Fernandes, Daniel; Resende, Celso; Cavalcanti, Jacqueline; Liu, Dexue; Elias, Carlos.
Afiliação
  • Fernandes D; Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ, 22290-270, Brazil. daniel.fernandes@unisa.edu.au.
  • Resende C; School of Engineering, University of South Australia, V Building, Office V1-17w15, Mawson Lakes, SA, 5095, Australia. daniel.fernandes@unisa.edu.au.
  • Cavalcanti J; Biomaterials Laboratory, Instituto Militar de Engenharia, Rio de Janeiro, RJ, 22290-270, Brazil.
  • Liu D; College of Veterinary Medicine, University of Florida, Gainesville, FL, 32610-0126, USA.
  • Elias C; State Key Laboratory of Advanced Processing and Recycling of Nonferrous Metals, Lanzhou University of Technology, Lanzhou, 730050, Gansu, China.
J Mater Sci Mater Med ; 30(12): 134, 2019 Dec 03.
Article em En | MEDLINE | ID: mdl-31797113
ABSTRACT
The objectives were to investigate the mechanical strength and biocompatibility of Mg2Ca2Gd and Mg1Ca2Nd (wt%) alloys developed for biomedical application as implantable bioabsorbable devices. Samples were implanted in New-Zealand rabbits tibia for 3, 6 and 8 weeks and compatibility analysis involved whole blood test, biochemistry, histopathology, histology, and radiographs. Refinement in grains were observed in Mg2Ca2Gd alloy; and Mg5Gd, Mg41Nd5, α-Mg and Mg2Ca phases were identified. Polarization curves revealed easier oxidation of Mg2Ca2Gd alloy, smaller values of corrosion rate and a higher polarization resistance of Mg1Ca2Nd. Adequate compatibility of both alloys was identified with pre-osteoblast stem cells. Red and white cells stayed compatible with reference ranges. Enzymes from liver and kidneys stayed at regular values and samples from kidneys and liver tissues presented similar organization to control animals. Histological displays from implantation sites disclosed well-structured tissues with evidences of bone cells activities compatible with the new bone tissues observed. Radiographs from tibias did not revealed relevant gas pockets. Mg2Ca2Gd alloy demonstrated faster degradation. Adequate biocompatibility was observed in Mg-Ca alloys with RE addition, being potential candidates for development of metallic implantable bioabsorbable devices.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Magnésio / Compostos de Cálcio / Ligas / Metais Terras Raras Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Compostos de Magnésio / Compostos de Cálcio / Ligas / Metais Terras Raras Limite: Animals Idioma: En Ano de publicação: 2019 Tipo de documento: Article