Your browser doesn't support javascript.
loading
Direct nano-electrospray ionization tandem mass spectrometry for the quantification and identification of metronidazole in its dosage form and human urine.
Amer, Sara; Zarad, Walaa; El-Gendy, Heba; Abdel-Salam, Randa; Hadad, Ghada; Masujima, Tsutomu; Emara, Samy.
Afiliação
  • Amer S; Faculty of Pharmacy, Misr International University, Km 28 Ismailia Road, Cairo 11865, Egypt.
  • Zarad W; Quantitative Biology Center (QBiC), RIKEN, 6-2-3 Furuedai, Suita, Osaka 565-0874, Japan.
  • El-Gendy H; Faculty of Pharmacy, Misr International University, Km 28 Ismailia Road, Cairo 11865, Egypt.
  • Abdel-Salam R; Faculty of Pharmacy, Misr International University, Km 28 Ismailia Road, Cairo 11865, Egypt.
  • Hadad G; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, University of Suez Canal, Ismailia 41522, Egypt.
  • Masujima T; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, University of Suez Canal, Ismailia 41522, Egypt.
  • Emara S; Quantitative Biology Center (QBiC), RIKEN, 6-2-3 Furuedai, Suita, Osaka 565-0874, Japan.
R Soc Open Sci ; 6(11): 191336, 2019 Nov.
Article em En | MEDLINE | ID: mdl-31827866
ABSTRACT
A rapid, sensitive and direct nano-electrospray ionization-tandem mass spectrometry (NS-ESI-MS/MS) method, using an offline nanospray (NS) capillary, has been developed and validated for the analysis of metronidazole (MTZ). A mixture of 2 µl MTZ sample solution prepared in an ionization solvent consisting of methanol water formic acid in a ratio of 80 20 0.3, together with 2 µl of an internal standard (IS), 1,3,6-polytyrosine, is loaded into the back of the NS capillary. The NS capillary was fitted into the ion source at a distance of 3 mm between the NS tip and MS orifice. The sample is then analysed and acquired a sustainable signal that allowed for data compilation across various data points for MTZ identification and quantification. The quantification relied on the ratio of the [M + H]+ peaks of MTZ and IS with m/z values of 172.0717 and 182.0812, respectively, while the identification relied on the MS/MS of the precursor ions [M + H]+ of both compounds and their fragments at 128.05 for MTZ and 165.1 and 136.07 for the IS. The NS-ESI-MS/MS method was accurate and precise for the quantification of MTZ over the concentration range from 2.5 to 25 000 ng ml-1. The applicability of the method was confirmed by MTZ analysis in its pharmaceutical dosage form and detection of the analyte in clinical human urine samples without any sample treatment procedure.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2019 Tipo de documento: Article