Three-Year Outcomes of a Randomized, Double-Blind, Placebo-Controlled Study Assessing Safety and Efficacy of C1 Esterase Inhibitor for Prevention of Delayed Graft Function in Deceased Donor Kidney Transplant Recipients.
Clin J Am Soc Nephrol
; 15(1): 109-116, 2020 01 07.
Article
em En
| MEDLINE
| ID: mdl-31843975
BACKGROUND AND OBJECTIVES: Delayed graft function is related to ischemia-reperfusion injury and may be complement dependent. We previously reported from a randomized, placebo-controlled trial that treatment with C1 esterase inhibitor was associated with a shorter duration of delayed graft function and higher eGFR at 1 year. Here, we report longer-term outcomes from this trial. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: This is a post hoc analysis of a phase 1/2, randomized, controlled trial enrolling 70 recipients of deceased donor kidney transplants at risk for delayed graft function (NCT02134314). Subjects were randomized to receive C1 esterase inhibitor 50 U/kg (n=35) or placebo (n=35) intraoperatively and at 24 hours. The cumulative incidence functions method was used to compare graft failure and death over 3.5 years. eGFR slopes were compared using a linear mixed effects model. RESULTS: Three deaths occurred among C1 esterase inhibitor-treated patients compared with none receiving placebo. Seven graft failures developed in the placebo group compared with one among C1 esterase inhibitor-treated recipients; the cumulative incidence of graft failure was lower over 3.5 years among C1 esterase inhibitor-treated recipients compared with placebo (P=0.03). Although no difference in eGFR slopes was observed between groups (P for group-time interaction =0.12), eGFR declined in placebo-treated recipients (-4 ml/min per 1.73 m2 per year; 95% confidence interval, -8 to -0.1) but was stable in C1 esterase inhibitor-treated patients (eGFR slope: 0.5 ml/min per 1.73 m2 per year; 95% confidence interval, -4 to 5). At 3.5 years, eGFR was 56 ml/min per 1.73 m2 (95% confidence interval, 42 to 70) in the C1 esterase inhibitor group versus 35 ml/min per 1.73 m2 (95% confidence interval, 21 to 48) in the placebo group, with an estimated mean eGFR difference of 21 ml/min per 1.73 m2 (95% confidence interval, 2 to 41 ml/min per 1.73 m2). CONCLUSIONS: Treatment of patients at risk for ischemia-reperfusion injury and delayed graft function with C1 esterase inhibitor was associated with a lower incidence of graft failure.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Traumatismo por Reperfusão
/
Transplante de Rim
/
Função Retardada do Enxerto
/
Proteína Inibidora do Complemento C1
/
Taxa de Filtração Glomerular
/
Rim
Tipo de estudo:
Clinical_trials
/
Etiology_studies
/
Incidence_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2020
Tipo de documento:
Article