Your browser doesn't support javascript.
loading
University of California Replacement of Cesium Irradiators with Alternative Technologies.
MacKenzie, Carolyn; Iwamoto, Keisuke S; Smith, Kenneth.
Afiliação
  • MacKenzie C; University of CA, Berkeley, Environment, Health & Safety, 2199 Addison Street, Suite 317 MC1150, Berkeley, CA 94720.
  • Iwamoto KS; University of California, Los Angeles, Los Angeles, CA.
  • Smith K; University of California, Office of the President, Oakland, CA.
Health Phys ; 118(2): 209-214, 2020 02.
Article em En | MEDLINE | ID: mdl-31869317
ABSTRACT
The University of California possesses a large number of Cs irradiators that are used in a wide variety of medical and research applications. The university president made a system-wide decision to reduce the potential threat of malevolent use of Cs by switching wherever feasible to x-ray irradiators over a 3-y period of time. A Radioactive Source Replacement Working Group of involved faculty was formed to study the topic and to make recommendations as to when alternative technologies could offer equivalency. The Working Group concluded that x-ray irradiators could replace Cs irradiators in most applications, with some likely exceptions. They found that the depth dose curve for the 320 kVp x-ray irradiator was found to be nearly identical to that of Cs down to a depth in tissue of 4 cm. It was concluded that x rays (energies ≤320 keV) are more biologically effective than Cs gamma rays, suggesting that lower doses of x rays will be required to achieve the same biological endpoint as Cs gamma rays. A simple conversion factor for equating x-ray effects to Cs effects was not recommended because relative biological effectiveness depends on multiple factors. They concluded that each experiment should be individually calibrated when converting from Cs irradiators to x-ray irradiators. The lessons learned from implementing the project to date have shown the importance of having senior management buy-in, involving the research community in the decision making process and allowing for exceptions where equivalency of Cs to x ray cannot be established.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Geradores de Radionuclídeos / Radioisótopos de Césio Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Geradores de Radionuclídeos / Radioisótopos de Césio Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article