A Practical Method for Ablation Catheter Reintroduction into the Left Atrium via Prior Transseptal Puncture, without Radiation.
Pang, Lingpin; Chen, Song-Wen; Zhou, Gen-Qing; Wei, Yong; Chen, Can; Huang, Shi-An; Liu, Shao-Wen.
Afiliação
  • Pang L; The First Affiliated Hospital, Jinan University, Guangzhou, Guangdong, China.
  • Chen SW; Department of Cardiology, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.
  • Zhou GQ; Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Wei Y; Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Chen C; Department of Cardiology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Huang SA; The First Affiliated Hospital, Jinan University, Guangzhou, Guangdong, China.
  • Liu SW; Department of Cardiology, Affiliated Hospital of Guangdong Medical University, Zhanjiang, Guangdong, China.
Heart Surg Forum ; 22(6): E470-E475, 2019 12 03.
Article em En | MEDLINE | ID: mdl-31895032
BACKGROUND: We evaluated the feasibility and safety of reintroducing an ablation catheter (ABL) into the left atrium (LA) through a previously punctured interatrial septum under guidance of the show-catheter image-track function of the CARTO 3 3-dimensional (3D) electroanatomic mapping system. METHODS: One hundred consecutive paroxysmal or persistent drug-refractory atrial fibrillation (AF) patients (men: 55; mean age, 64.7 ± 12.1 years) who had undergone 2 fluoroscopy-guided transseptal punctures and anatomical LA reconstruction under CARTO 3-guidance, and required ABL reinsertion into the LA during mapping or ablation, were included. They were randomized 1:1 to the show-catheter (reintroduction under the CARTO 3 show-catheter image-track function) or fluoroscopy group (reintroduction under conventional fluoroscopy). RESULTS: Although the reconstructed 3D anatomy map was displaced in 21/100 patients (21.0%), the ABL was successfully reintroduced in all patients. In the show-catheter and fluoroscopy groups, model displacement incidence (18% versus 24%), tachyarrhythmias (46.0% versus 52.0%), complications (2% versus 4%), and number of ABLs reintroduced into the LA (3.3 ± 0.8 versus 3.1 ± 0.9) were similar (all P > .05). The show-catheter group displayed shorter ABL reintroduction time (9.5 ± 5.5 s versus 156.4 ± 35.5 s, P < .01), ABL reintroduction X-ray exposure time (0 s versus 39.3 ± 13.8 s, P < .01), and total X-ray exposure time (4.1 ± 1.4 min versus 4.7 ± 0.8, P < .05). CONCLUSION: During AF ablation, the catheter can be safely reintroduced into the LA, without additional fluoroscopy, under guidance of the CARTO 3 show-catheter image track function.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Ablação por Cateter / Técnicas de Imagem Cardíaca / Átrios do Coração Tipo de estudo: Clinical_trials Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2019 Tipo de documento: Article