Your browser doesn't support javascript.
loading
DNA damage response in peripheral mouse blood leukocytes in vivo after variable, low-dose rate exposure.
Wang, Qi; Pujol-Canadell, Monica; Taveras, Maria; Garty, Guy; Perrier, Jay; Bueno-Beti, Carlos; Shuryak, Igor; Brenner, David J; Turner, Helen C.
Afiliação
  • Wang Q; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA. qw2232@cumc.columbia.edu.
  • Pujol-Canadell M; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Taveras M; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Garty G; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Perrier J; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Bueno-Beti C; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Shuryak I; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Brenner DJ; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
  • Turner HC; Center for Radiological Research, Columbia University Irving Medical Center, New York, NY, 10032, USA.
Radiat Environ Biophys ; 59(1): 89-98, 2020 03.
Article em En | MEDLINE | ID: mdl-31897603
ABSTRACT
Environmental contamination and ingestion of the radionuclide Cesium-137 (137Cs) is a large concern in fallout from a nuclear reactor accident or improvised nuclear device, and highlights the need to develop biological assays for low-dose rate, internal emitter radiation. To mimic low-dose rates attributable to fallout, we have developed a VAriable Dose-rate External 137Cs irradiatoR (VADER), which can provide arbitrarily varying and progressive low-dose rate irradiations in the range of 0.1-1.2 Gy/day, while circumventing the complexities of dealing with radioactively contaminated biomaterials. We investigated the kinetics of mouse peripheral leukocytes DNA damage response in vivo after variable, low-dose rate 137Cs exposure. C57BL/6 mice were placed in the VADER over 7 days with total accumulated dose up to 2.7 Gy. Peripheral blood response including the leukocyte depletion, apoptosis as well as its signal protein p53 and DNA repair biomarker γ-H2AX was measured. The results illustrated that blood leukocyte numbers had significantly dropped by day 7. P53 levels peaked at day 2 (total dose = 0.91 Gy) and then declined; whereas, γ-H2AX fluorescence intensity (MFI) and foci number generally increased with accumulated dose and peaked at day 5 (total dose = 2.08 Gy). ROC curve analysis for γ-H2AX provided a good discrimination of accumulated dose < 2 Gy and ≥ 2 Gy, highlighting the potential of γ-H2AX MFI as a biomarker for dosimetry in a protracted, environmental exposure scenario.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dano ao DNA / Histonas / Radioisótopos de Césio / Leucócitos Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Dano ao DNA / Histonas / Radioisótopos de Césio / Leucócitos Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article