Your browser doesn't support javascript.
loading
Mass Spectrometry Imaging of atherosclerosis-affine Gadofluorine following Magnetic Resonance Imaging.
Lohöfer, Fabian; Buchholz, Rebecca; Glinzer, Almut; Huber, Katharina; Haas, Helena; Kaissis, Georgios; Feuchtinger, Annette; Aichler, Michaela; Sporns, Peter B; Höltke, Carsten; Stölting, Miriam; Schilling, Franz; Botnar, René M; Kimm, Melanie A; Faber, Cornelius; Walch, Axel K; Zernecke, Alma; Karst, Uwe; Wildgruber, Moritz.
Afiliação
  • Lohöfer F; Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Buchholz R; Department for Analytical Chemistry, Westfälische Wilhelms-Universität, Münster, Germany.
  • Glinzer A; Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Huber K; Research Unit Analytical Pathology, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg, Germany.
  • Haas H; Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Kaissis G; Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Feuchtinger A; Research Unit Analytical Pathology, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg, Germany.
  • Aichler M; Research Unit Analytical Pathology, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg, Germany.
  • Sporns PB; Translational Research Imaging Center, Department of Clinical Radiology, Westfälische Wilhelms-Universität, Münster, Germany.
  • Höltke C; Translational Research Imaging Center, Department of Clinical Radiology, Westfälische Wilhelms-Universität, Münster, Germany.
  • Stölting M; Translational Research Imaging Center, Department of Clinical Radiology, Westfälische Wilhelms-Universität, Münster, Germany.
  • Schilling F; Department of Nuclear Medicine, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Botnar RM; School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
  • Kimm MA; Department of Diagnostic and Interventional Radiology, School of Medicine & Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
  • Faber C; Translational Research Imaging Center, Department of Clinical Radiology, Westfälische Wilhelms-Universität, Münster, Germany.
  • Walch AK; DFG Cluster of Excellence EXC 1003 'Cells in Motion', Münster, Germany.
  • Zernecke A; Research Unit Analytical Pathology, German Research Center for Environmental Health, Helmholtz Zentrum München, Neuherberg, Germany.
  • Karst U; Institute for Experimental Biomedicine, Universitätsklinikum Würzburg, Würzburg, Germany.
  • Wildgruber M; Department for Analytical Chemistry, Westfälische Wilhelms-Universität, Münster, Germany.
Sci Rep ; 10(1): 79, 2020 01 09.
Article em En | MEDLINE | ID: mdl-31919465
ABSTRACT
Molecular imaging of atherosclerosis by Magnetic Resonance Imaging (MRI) has been impaired by a lack of validation of the specific substrate responsible for the molecular imaging signal. We therefore aimed to investigate the additive value of mass spectrometry imaging (MSI) of atherosclerosis-affine Gadofluorine P for molecular MRI of atherosclerotic plaques. Atherosclerotic Ldlr-/- mice were investigated by high-field MRI (7 T) at different time points following injection of atherosclerosis-affine Gadofluorine P as well as at different stages of atherosclerosis formation (4, 8, 16 and 20 weeks of HFD). At each imaging time point mice were immediately sacrificed after imaging and aortas were excised for mass spectrometry imaging Matrix Assisted Laser Desorption Ionization (MALDI) Imaging and Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry (LA-ICP-MS) imaging. Mass spectrometry imaging allowed to visualize the localization and measure the concentration of the MR imaging probe Gadofluorine P in plaque tissue ex vivo with high spatial resolution and thus adds novel and more target specific information to molecular MR imaging of atherosclerosis.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Receptores de LDL / Imageamento por Ressonância Magnética / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Meios de Contraste / Aterosclerose / Complexos de Coordenação / Imagem Molecular / Fluorocarbonos Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Receptores de LDL / Imageamento por Ressonância Magnética / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Meios de Contraste / Aterosclerose / Complexos de Coordenação / Imagem Molecular / Fluorocarbonos Limite: Animals Idioma: En Ano de publicação: 2020 Tipo de documento: Article