Your browser doesn't support javascript.
loading
Increased 18F-FDG signal recovery from small physiological structures in digital PET/CT and application to the pituitary gland.
Meyer, Marie; Allenbach, Gilles; Nicod Lalonde, Marie; Schaefer, Niklaus; Prior, John O; Gnesin, Silvano.
Afiliação
  • Meyer M; Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland.
  • Allenbach G; Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland.
  • Nicod Lalonde M; Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland. Marie.Nicod-Lalonde@chuv.ch.
  • Schaefer N; Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland.
  • Prior JO; Department of Nuclear Medicine and Molecular Imaging, Lausanne University Hospital, Lausanne, Switzerland.
  • Gnesin S; Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.
Sci Rep ; 10(1): 368, 2020 01 15.
Article em En | MEDLINE | ID: mdl-31942032
ABSTRACT
On conventional PET/CT, and under physiological conditions, the volume of the pituitary gland (PG) is small, and its metabolic activity is commonly comparable to the surrounding background level in 18F-FDG imaging. We compared the physiological 18F-FDG uptake of the PG in patients imaged with digital PET (dPET) and with conventional PET (cPET). Additionally, we performed phantom experiments to characterize signal recovery and detectability of small structures. We retrospectively included 10 dPET and 10 cPET patients and measured PG SUVmax, SUVmean and SUVratio (using cerebellum as reference). We imaged a modified NEMA/IEC phantom with both dPET and cPET (background activity 5 kBq/mL, and 3× and 5× higher concentrations in ∅2-20-mm spherical inserts). Mean recovery coefficients (RCmean) and signal-difference-to-noise-ratio (SDNR) were computed to assess lesion detectability. Patients imaged with dPET presented higher PG SUVmax and SUVratio (SUVR) compared to patients imaged with cPET (4.7 ± 2.05 vs. 2.9 ± 0.64, p = 0.004; and 0.62 ± 0.25 vs 0.39 ± 0.09, p = 0.029, respectively), while there was no difference for SUVmean (2.7 ± 1.32 vs 2.1 ± 0.44, p = 0.39). Thus, with a SUV readout scale of 0-5 g/mL, normal PG appeared abnormally hot with dPET, but not with cPET. Phantom evidenced higher RCmean in dPET compared to cPET. For both 3x and 5x measurements, lesion detectability according to size was systematically superior with dPET. In conclusion, patients imaged with dPET presented higher 18F-FDG physiological uptake of the PG as compared to patients imaged with cPET. These findings were supported by phantom experiments demonstrating superior signal recovery and small region detectability with dPET. Awareness of this new "higher" SUV of the normal 18F-FDG uptake of the PG is important to avoid potential pitfalls in image interpretation, notably in oncologic patients treated with immunotherapy, who are at increased risk to develop hypophysitis.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças da Hipófise / Hipófise / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doenças da Hipófise / Hipófise / Fluordesoxiglucose F18 / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article