Your browser doesn't support javascript.
loading
An Efficient and Cost-Effective Nose-Only Inhalational Chamber for Rodents: Design, Optimization and Validation.
Kaur, Ranjot; Kaushik, Anupama; Singh, Kamalinder K; Katare, O P; Singh, Bhupinder.
Afiliação
  • Kaur R; University Institute of Pharmaceutical Sciences, UGC Centre of Advanced Studies, Panjab University, Chandigarh, 160 014, India.
  • Kaushik A; School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
  • Singh KK; Dr. S.S. Bhatnagar University Institute of Chemical Engineering and Technology, Panjab University, Chandigarh, 160 014, India.
  • Katare OP; School of Pharmacy and Biomedical Sciences, University of Central Lancashire, Preston, PR1 2HE, UK.
  • Singh B; University Institute of Pharmaceutical Sciences, UGC Centre of Advanced Studies, Panjab University, Chandigarh, 160 014, India.
AAPS PharmSciTech ; 21(3): 82, 2020 Jan 27.
Article em En | MEDLINE | ID: mdl-31989357
ABSTRACT
The mainstay treatment of pulmonary disorders lies around the direct drug targeting to the lungs using a nebulizer, metered-dose inhaler, or dry powder inhaler. Only few inhalers are available in the market that could be used for inhalational drug delivery in rodents. However, the available rodent inhalers invariably require high cost and maintenance, which limits their use at laboratory scale. The present work, therefore, was undertaken to develop a simple, reliable, and cost-effective nose-only inhalation chamber with holding capacity of three mice at a time. The nebulized air passes directly and continuously from the central chamber to mouthpiece and maintains an aerosol cloud for rodents to inhale. Laser diffraction analysis indicated volume mean diameter of 4.02 ± 0.30 µm, and the next-generation impactor studies, however, revealed mean mass aerodynamic diameter of 3.40 ± 0.27 µm, respectively. An amount of 2.05 ± 0.20 mg of voriconazole (VRC) was available for inhalation at each delivery port of the inhaler. In vivo studies indicated the deposition of 76.12 ± 19.50 µg of VRC in the mice lungs when nebulized for a period of 20 min. Overall, the developed nose-only inhalation chamber offers a reliable means of generating aerosols and successfully exposing mice to nebulization.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores Tipo de estudo: Health_economic_evaluation Limite: Animals / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Nebulizadores e Vaporizadores Tipo de estudo: Health_economic_evaluation Limite: Animals / Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article