Your browser doesn't support javascript.
loading
Double-tuned 31 P/1 H human head array with high performance at both frequencies for spectroscopic imaging at 9.4T.
Avdievich, Nikolai I; Ruhm, Loreen; Dorst, Johanna; Scheffler, Klaus; Korzowski, Andreas; Henning, Anke.
Afiliação
  • Avdievich NI; High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Ruhm L; High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Dorst J; High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Scheffler K; High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.
  • Korzowski A; Department for Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany.
  • Henning A; Department for Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany.
Magn Reson Med ; 84(2): 1076-1089, 2020 08.
Article em En | MEDLINE | ID: mdl-32003031
ABSTRACT

PURPOSE:

To develop a robust design of a human head double-tuned 31 P/1 H array, which provides good performance at both 31 P and 1 H frequencies for MR spectroscopic imaging at 9.4T.

METHODS:

Increasing the number of surface loops in a human head array improves the peripheral signal-to-noise ratio (SNR), while the central SNR doesn't substantially change. High peripheral SNR can contaminate MR spectroscopic imaging data at both 1 H and 31 P frequency. To minimize this effect, we limited the number of elements in the 31 P array to 10, i.e., 8 transceiver surface loops circumscribing the head and 2 receive "vertical" loops placed at the superior location. The 1 H-portion of the array also consists of 10 elements, i.e., 8 transceiver surface loops circumscribing the head and 2 transceiver "vertical" loops at the superior location of the head. Both the 31 P array and 1 H array are placed in a single layer at the same distance to the head, which provides high loading and, thus, a good performance for both arrays.

RESULTS:

Transmit efficiency of the 1 H-portion of the double-tuned array was very similar to that of the single-tuned arrays of similar size. Also, addition of the cross-loops substantially improved the brain coverage.

CONCLUSION:

We developed a novel 31 P/1 H double-tuned array for MR spectroscopic imaging of a human brain at 9.4T. Placing both 31 P and 1 H loops in a single layer provides for high transmit efficiency at both frequencies without compromising SNR near the brain center at the 31 P-frequency. Addition of the cross-loops at the superior location improves the brain coverage.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cabeça Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Cabeça Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article