OBJECTIVES:
Recent guidance recommended use of high-sensitivity troponin for rapid rule out of myocardial infarction (MI) in the English health service. We aimed to determine the extent of implementation of this guidance across English hospitals.METHODS:
This study conducted a cross-sectional questionnaire survey of 131 English acute hospitals with over 10 000 admissions per year.RESULTS:
We received 125/131 responses (95%), with 110/125 (88%) reporting use of a high-sensitivity troponin assay and responses showing progressive implementation over the last 10 years. High-sensitivity troponin was reported to be used for rapid rule out of MI in 92/110 Trusts (84%). Review of guidelines received from 95/110 Trusts identified that 71/95 (75%) provided guidance for rapid MI rule out with high-sensitivity troponin 57 recommended testing at 0 and 3 hours, 4 recommended testing at 0 and 2 hours, and 9 recommended testing at 0 and 1 hour, and timing was unclear at one Trust.CONCLUSIONS:
English acute hospital Trusts report widespread implementation of high-sensitivity troponin for rapid rule out of MI, with most recommending testing at 0 and 3 hours.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Troponina
/
Resultados Negativos
/
Infarto do Miocárdio
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Prevalence_studies
/
Prognostic_studies
/
Qualitative_research
/
Risk_factors_studies
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
País como assunto:
Europa
Idioma:
En
Ano de publicação:
2020
Tipo de documento:
Article