Your browser doesn't support javascript.
loading
Development of a dual-energy X-ray absorptiometry-derived body volume equation in Hispanic adults for administering a four-compartment model.
Nickerson, Brett S; Fedewa, Michael V; McLester, Cherilyn N; McLester, John R; Esco, Michael R.
Afiliação
  • Nickerson BS; College of Nursing and Health Sciences, Texas A&M International University, Laredo, TX, USA.
  • Fedewa MV; Department of Kinesiology, The University of Alabama, Tuscaloosa, AL, USA.
  • McLester CN; Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, USA.
  • McLester JR; Department of Exercise Science and Sport Management, Kennesaw State University, Kennesaw, GA, USA.
  • Esco MR; Department of Kinesiology, The University of Alabama, Tuscaloosa, AL, USA.
Br J Nutr ; 123(12): 1373-1381, 2020 06 28.
Article em En | MEDLINE | ID: mdl-32077390
ABSTRACT
The purpose of the present study was (1) to develop a new dual-energy X-ray absorptiometry (DXA)-derived body volume (BV) equation with the GE-Lunar prodigy while utilising underwater weighing (UWW) as a criterion and (2) to cross-validate the novel DXA-derived BV equation (4C-DXANickerson), Wilson DXA-derived BV equation (4C-DXAWilson) and air displacement plethysmography (ADP)-derived BV (4C-ADP) in Hispanic adults. A total of 191 Hispanic adults (18-45 years) participated in the present study. The development sample consisted of 120 females and males (50 % females), whereas the cross-validation sample comprised of forty-one females and thirty males (n 71). Criterion body fat percentage (BF %) and fat-free mass (FFM) were determined using a four-compartment (4C) model with UWW as a criterion for BV (4C-UWW). 4C-DXANickerson, 4C-DXAWilson and 4C-ADP were compared against 4C-UWW in the cross-validation sample. 4C-DXANickerson, 4C-DXAWilson and 4C-ADP all produced similar validity statistics when compared with 4C-UWW in Hispanic males (all P > 0·05). 4C-DXANickerson also yielded similar BF % and FFM values as 4C-UWW when evaluating the mean differences (constant error (CE)) in Hispanic females (CE = -0·79 % and 0·38 kg; P = 0·060 and 0·174, respectively). However, 4C-DXAWilson produced significantly different BF % and FFM values (CE = 3·22 % and -2·20 kg, respectively; both P < 0·001). Additionally, 4C-DXAWilson yielded significant proportional bias when estimating BF % (P < 0·001), whereas 4C-ADP produced significant proportional bias for BF % and FFM (both P < 0·05) when evaluated in Hispanic females. The present study findings demonstrate that 4C-DXANickerson is a valid measure of BV in Hispanics and is recommended for use in clinics, where DXA is the main body composition assessment technique.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Composição Corporal / Peso Corporal / Hispânico ou Latino / Absorciometria de Fóton / Modelos Biológicos Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Composição Corporal / Peso Corporal / Hispânico ou Latino / Absorciometria de Fóton / Modelos Biológicos Tipo de estudo: Prognostic_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2020 Tipo de documento: Article