Your browser doesn't support javascript.
loading
Biomechanical comparison of plantar-to-dorsal and dorsal-to-plantar screw fixation strength for subtalar arthrodesis.
Chaudhari, Nileshkumar; Godoy-Santos, Alexandre Leme; Netto, Cesar de Cesar; Rodriguez, Ramon; Dun, Shouchen; He, Jun Kit; McKissack, Haley; Fleisig, Glenn S; Pires, Eduardo Araujo; Shah, Ashish.
Afiliação
  • Chaudhari N; University of Alabama at Birmingham , Birmingham , AL , United States .
  • Godoy-Santos AL; Hospital Israelita Albert Einstein , São Paulo , SP , Brazil .
  • Netto CC; Hospital das Clínicas , Faculdade de Medicina , Universidade de São Paulo , São Paulo , SP , Brazil .
  • Rodriguez R; University of Iowa Health Care , Carver College of Medicine , Iowa City , Iowa , United States .
  • Dun S; Tulane University Orthopaedics , New Orleans , LA , United States .
  • He JK; University of Alabama at Birmingham , Birmingham , AL , United States .
  • McKissack H; University of Alabama at Birmingham , Birmingham , AL , United States .
  • Fleisig GS; University of Alabama at Birmingham , Birmingham , AL , United States .
  • Pires EA; American Sports Medicine Institute , Birmingham , AL , United States .
  • Shah A; Hospital Israelita Albert Einstein , São Paulo , SP , Brazil .
Einstein (Sao Paulo) ; 18: e0AO5052, 2020.
Article em En, Pt | MEDLINE | ID: mdl-32159606
ABSTRACT

OBJECTIVE:

To compare screw fixation strength for subtalar arthrodesis.

METHODS:

Eight matched pairs of cadaver feet underwent subtalar joint arthrodesis with two 7.3mm cannulated screws. Randomization was used to assign screw orientation, such that one foot in each pair was assigned dorsal to plantar screw orientation (DP Group), and the other foot, plantar to dorsal orientation (PD Group). Standard surgical technique with fluoroscopy was used for each approach. Following fixation, each specimen was loaded to failure with a Bionix ® 858 MTS device, applying a downward axial force at a distance to create torque. Torque to failure was compared between DP and PD Groups using Student's t test, with p=0.05 used to determine statistical significance.

RESULTS:

Statistical analysis demonstrated that the mean torque to failure slightly favored the DP Group (37.3Nm) to the PD Group (32.2Nm). However, the difference between the two groups was not statistically significant (p=0.55).

CONCLUSION:

In subtalar arthrodesis, there is no significant difference in construct strength between dorsal-to-plantar and plantar-to-dorsal screw orientation. The approach chosen by the surgeon should be based on factors other than the biomechanical strength of the screw orientation.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrodese / Parafusos Ósseos / Articulação Talocalcânea Tipo de estudo: Clinical_trials / Evaluation_studies Limite: Humans Idioma: En / Pt Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrodese / Parafusos Ósseos / Articulação Talocalcânea Tipo de estudo: Clinical_trials / Evaluation_studies Limite: Humans Idioma: En / Pt Ano de publicação: 2020 Tipo de documento: Article