Small eye movements cannot be reliably measured by video-based P-CR eye-trackers.
Holmqvist, Kenneth; Blignaut, Pieter.
Afiliação
  • Holmqvist K; Institute of Psychology, Nicolaus Copernicus University in Torun, Torun, Poland. kenneth.holmqvist@ur.de.
  • Blignaut P; Department of Psychology, Regensburg University, Regensburg, Germany. kenneth.holmqvist@ur.de.
Behav Res Methods ; 52(5): 2098-2121, 2020 10.
Article em En | MEDLINE | ID: mdl-32206998
ABSTRACT
For evaluating whether an eye-tracker is suitable for measuring microsaccades, Poletti & Rucci (2016) propose that a measure called 'resolution' could be better than the more established root-mean-square of the sample-to-sample distances (RMS-S2S). Many open questions exist around the resolution measure, however. Resolution needs to be calculated using data from an artificial eye that can be turned in very small steps. Furthermore, resolution has an unclear and uninvestigated relationship to the RMS-S2S and STD (standard deviation) measures of precision (Holmqvist & Andersson, 2017, p. 159-190), and there is another metric by the same name (Clarke, Ditterich, Drüen, Schönfeld, and Steineke 2002), which instead quantifies the errors of amplitude measurements. In this paper, we present a mechanism, the Stepperbox, for rotating artificial eyes in arbitrary angles from 1' (arcmin) and upward. We then use the Stepperbox to find the minimum reliably detectable rotations in 11 video-based eye-trackers (VOGs) and the Dual Purkinje Imaging (DPI) tracker. We find that resolution correlates significantly with RMS-S2S and, to a lesser extent, with STD. In addition, we find that although most eye-trackers can detect some small rotations of an artificial eye, the rotations of amplitudes up to 2∘ are frequently erroneously measured by video-based eye-trackers. We show evidence that the corneal reflection (CR) feature of these eye-trackers is a major cause of erroneous measurements of small rotations of artificial eyes. Our data strengthen the existing body of evidence that video-based eye-trackers produce errors that may require that we reconsider some results from research on reading, microsaccades, and vergence, where the amplitude of small eye movements have been measured with past or current video-based eye-trackers. In contrast, the DPI reports correct rotation amplitudes down to 1'.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Gravação em Vídeo / Olho Artificial / Movimentos Oculares / Tecnologia de Rastreamento Ocular Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Gravação em Vídeo / Olho Artificial / Movimentos Oculares / Tecnologia de Rastreamento Ocular Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article