Your browser doesn't support javascript.
loading
Contact lens-based lysozyme detection in tear using a mobile sensor.
Ballard, Zachary; Bazargan, Sarah; Jung, Diane; Sathianathan, Shyama; Clemens, Ashley; Shir, Daniel; Al-Hashimi, Saba; Ozcan, Aydogan.
Afiliação
  • Ballard Z; Department of Electrical and Computer Engineering, University of California, Los Angeles, USA. ozcan@ucla.edu.
Lab Chip ; 20(8): 1493-1502, 2020 04 21.
Article em En | MEDLINE | ID: mdl-32227027
ABSTRACT
We report a method for sensing analytes in tear-fluid using commercial contact lenses (CLs) as sample collectors for subsequent analysis with a cost-effective and field-portable reader. In this study we quantify lysozyme, the most prevalent protein in tear fluid, non-specifically bound to CLs worn by human participants. Our mobile reader uses time-lapse imaging to capture an increasing fluorescent signal in a standard well-plate, the rate-of-change of which is used to indirectly infer lysozyme concentration through the use of a standard curve. We empirically determined the best-suited CL material for our sampling procedure and assay, and subsequently monitored the lysozyme levels of nine healthy human participants over a two-week period. Of these participants who were regular CL wearers (6 out of 9), we observed an increase in lysozyme levels from 6.89 ± 2.02 µg mL-1 to 10.72 ± 3.22 µg mL-1 (mean ± SD) when inducing an instance of digital eye-strain by asking them to play a game on their mobile-phones during the CL wear-duration. We also observed a lower mean lysozyme concentration (2.43 ± 1.66 µg mL-1) in a patient cohort with dry eye disease (DED) as compared to the average monitoring level of healthy (no DED) human participants (6.89 ± 2.02 µg mL-1). Taken together, this study demonstrates tear-fluid analysis with simple and non-invasive sampling steps along with a rapid, easy-to-use, and cost-effective measurement system, ultimately indicating physiological differences in human participants. We believe this method could be used in future tear-fluid studies, even supporting multiplexed detection of a panel of tear biomarkers toward improved diagnostics and prognostics as well as personalized mobile-health applications.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Síndromes do Olho Seco / Lentes de Contato Hidrofílicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Síndromes do Olho Seco / Lentes de Contato Hidrofílicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2020 Tipo de documento: Article