Your browser doesn't support javascript.
loading
Model Predictive Control via Output Feedback Neural Network for Improved Multi-Window Greenhouse Ventilation Control.
Jung, Dae-Hyun; Kim, Hak-Jin; Kim, Joon Yong; Lee, Taek Sung; Park, Soo Hyun.
Afiliação
  • Jung DH; Smart Farm Research Center, Korea Institute of Science and Technology (KIST), Gangneung-si, Gangwon-do 25451, Korea.
  • Kim HJ; Department of Biosystems and Biomaterial Engineering, College of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea.
  • Kim JY; Department of Biosystems and Biomaterial Engineering, College of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea.
  • Lee TS; Department of Biosystems and Biomaterial Engineering, College of Agriculture and Life Sciences, Seoul National University, Seoul 08826, Korea.
  • Park SH; Smart Farm Research Center, Korea Institute of Science and Technology (KIST), Gangneung-si, Gangwon-do 25451, Korea.
Sensors (Basel) ; 20(6)2020 Mar 22.
Article em En | MEDLINE | ID: mdl-32235737
Maintaining environmental conditions for proper plant growth in greenhouses requires managing a variety of factors; ventilation is particularly important because inside temperatures can rise rapidly in warm climates. The structure of the window installed in a greenhouse is very diverse, and it is difficult to identify the characteristics that affect the temperature inside the greenhouse when multiple windows are driven, respectively. In this study, a new ventilation control logic using an output feedback neural-network (OFNN) prediction and optimization method was developed, and this approach was tested in multi-window greenhouses used for strawberry production. The developed prediction model used 15 inputs and achieved a highly accurate performance (R2 of 0.94). In addition, the method using an algorithm based on an OFNN was proposed for optimizing considered six window-opening behavior. Three case studies confirmed the optimization performance of OFNN in the nonlinear model and verified the performance through simulations. Finally, a control system based on this logic was used in a field experiment for six days by comparing two greenhouses driven by conventional control logic and the developed control logic; a comparison of the results showed RMSEs of 3.01 °C and 2.45 °C, respectively. It confirmed the improved control performance in comparison to a conventional ventilation control system.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2020 Tipo de documento: Article