Retrospective quality metrics review of stereotactic radiosurgery plans treating multiple targets using single-isocenter volumetric modulated arc therapy.
Cui, Yunfeng; Gao, Hao; Zhang, Jiahan; Kirkpatrick, John P; Yin, Fang-Fang.
Afiliação
  • Cui Y; Department of Radiation Oncology, Duke University, Durham, NC, USA.
  • Gao H; Department of Radiation Oncology, Emory University, Atlanta, GA, USA.
  • Zhang J; Department of Radiation Oncology, Duke University, Durham, NC, USA.
  • Kirkpatrick JP; Department of Radiation Oncology, Duke University, Durham, NC, USA.
  • Yin FF; Department of Radiation Oncology, Duke University, Durham, NC, USA.
J Appl Clin Med Phys ; 21(6): 93-99, 2020 Jun.
Article em En | MEDLINE | ID: mdl-32239746
ABSTRACT

PURPOSE:

To characterize key plan quality metrics in multi-target stereotactic radiosurgery (SRS) plans treated using single-isocenter volumetric modulated arc therapy (VMAT) in comparison to dynamic conformal arc (DCA) plans treating single target. To investigate the feasibility of quality improvement in VMAT planning based on previous planning knowledge. MATERIALS AND

METHODS:

97 VMAT plans of multi-target and 156 DCA plans of single-target treated in 2017 at a single institution were reviewed. A total of 605 targets were treated with these SRS plans. The prescription dose was normalized to 20 Gy in all plans for this analysis. Two plan quality metrics, target conformity index (CI) and normal tissue volume receiving more than 12 Gy (V12Gy), were calculated for each target. The distribution of V12Gy per target was plotted as a function of the target volume. For multi-target VMAT plans, the number of targets being treated in the same plan and the distance between targets were calculated to evaluate their impact on V12Gy. VMAT plans that had a large deviation of V12Gy from the average level were re-optimized to determine the possibility of reducing the variation of V12Gy in VMAT planning.

RESULTS:

Conformity index of multi-target VMAT plans were lower than that of DCA plans while the mean values of 12 Gy were comparable. The V12Gy for a target in VMAT plan did not show apparent dependence on the total number of targets or the distance between targets. The distribution of V12Gy exhibited a larger variation in VMAT plans compared to DCA plans. Re-optimization of outlier plans reduced V12 Gy by 33.9% and resulted in the V12Gy distribution in VMAT plans more closely resembling that of DCA plans.

CONCLUSION:

The benchmark data on key plan quality metrics were established for single-isocenter multi-target SRS planning. It is feasible to use this knowledge to guide VMAT planning and reduce high V12Gy outliers.